Instruction manual
TABLE 22.3
TABLE 2.3 J1 Parallel I//O
TABLE 2.3 J1 Parallel I/O Pins
Pin Direction Functional Description
1 output RF AMP1 status; normally closed (to pin 20); opens if a fault is detected from AMP1
20 output RF AMP1 status; common for AMP1 fault indicators
2 output RF AMP1 status; normally open (to pin 20); closes if a fault is detected from AMP1
21 output RF AMP2 status; normally closed (to pin 3); opens if a fault is detected from AMP2
3 output RF AMP2 status; common for AMP2 fault indicators
22 output RF AMP2 status; normally open (to pin 3); closes if a fault is detected from AMP2
25 output AUTO indication; closed (to pin 6) when in AUTO mode
6 output AUTO/MANUAL mode indication; common for AUTO/MANUAL indication
24 output MANUAL indication; closed (to pin 6) when in MANUAL mode
7 output REMOTE mode indication; normally closed (to pin 26); open when in REMOTE mode
26 output REMOTE mode indication; common for REMOTE indication
8 output REMOTE mode indication; normally open (to pin 26); closed when in REMOTE mode
27 output SW1 - POSITION 1 indication; closed (to pin 9) when SW1 is in POSITION 1
9 output SW1 - POSITION indication; common
28 output SW1 - POSITION 2 indication; closed (to pin 9) when SW1 is in POSITION 2
31 output PS1 ALARM; normally closed (to pin 12); open when a Power Supply 1 fault occurs
12 output PS1 ALARM; common
30 output PS1 ALARM; normally open (to pin 12); closed when a Power Supply 1 fault occurs
14 output PS2 ALARM; normally closed (to pin 32); open when a Power Supply 2 fault occurs
32 output PS2 ALARM; common
13 output PS2 ALARM; normally open (to pin 32); closed when a Power Supply 2 fault occurs
16 input AUXILIARY; Ground to activate
18 input AUTO/MANUAL SELECT; Ground to activate MANUAL mode
36 input AMP2 STANDBY; Ground to activate
37 input AMP1 STANDBY; Ground to activate
19 output GROUND
2082-14x-47 Manual, Rev. B Page 17 12/19/13