Instruction manual

1.4.4 REMOTE
To override auto switching remotely…
[The unit must be in the REMOTE mode to execute any remote commands.]
From the serial M&C Interface:
1) SET the unit to MANUAL mode through the following command…
{aaC9x}
where x = 1 sets switch to MANUAL.
2) To manually test the switches, send the following remote M&C command to the unit.
{aaCAx}
where x = 1 sets switch to position 1 (Primary active),
and x = 2 sets switch to position 2 (Backup active.)
3) When testing is completed, return the unit to AUTO mode through the following command…
{aaC9x}
where x = 0 sets switch to AUTO.
From the (optional) Ethernet Interface:
Webpage:
1. Select “Manual” control mode.
2. Select “Remote” control mode.
3. Select the desired set position, either 1 to 1 or 2 to 1.
4. Click “Update Other”.
SNMP:
1. Set ObjectID ctrlMode to 1 (MANUAL).
2. Set ObjectID ctrlSource to 1 (REMOTE).
3. Set ObjectID switchPos to the desired position, either 1 (AMP1 to 1) or 2 (AMP2 to 1).
2082-14x-47 Manual, Rev. B Page 11 12/19/13