Model 2015-58 Instruction Manual Upconverter June 2014, Rev. F MODEL 2015 F = 5950.000 G = +10.0 UPCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE REMOTE POWER MUTE ALARM Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc.
INSTRUCTION MANUAL MODEL 2015-58 Upconverter TABLE OF CONTENTS PAGE Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Characteristics 1.3 Monitor & Control Interface 1.4 Use Information 2.0 Installation 2.1 Mechanical 2.2 Rear Inputs & Outputs 2.3 Front Panel Controls & Indicators 2.4 Operation 2.5 Menu Settings 2 3 3 4 5 7 8 8 9 9 10 11 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc.
MODEL 2015-58 Upconverter 1.0 General 1.1 Equipment Description The 2015-58 Upconverter converts 70 ± 18 MHz to 5.85 to 6.425 GHz in 125 kHz steps with low group delay and flat frequency response. Synthesized local oscillators (LO) provide low phase noise and ±0.01 ppm stability frequency selection. Push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), remote operation (yellow), PLL alarm (red), or the TX carrier is muted (yellow).
1.2 Technical Characteristics TABLE 1.
1.3 Monitor and Control Interface A) Remote Serial Interface Protocol - RS-485, RS-422 or RS-232C (selectable), 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit.
B) Commands - Table 1.2 lists the commands for the 2015-58 and briefly describes them. After a command is sent the 2015-58 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...
1.4 Use Information A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. C.
2.0 Installation 2.1 Mechanical The 2015-58 consists of one RF/Controller PCB which is housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ± 12, +24, +5 VDC power supply provides power for the assembly. The 2015-58 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 2015-58 is assembled. POWER SUPPLY PCB FIGURE 2.1 2015-58 Manual_Rev.
2.2 Rear Panel Input / Output Signals - Figure 2.2 shows the input and output connectors on the rear panel. J18 - 10 MHz REF OUTPUT 10 MHz reference output, 3 ± 3 dBm, 50/75 ohms BNC (female) connector. J10 - MONITOR AND CONTROL DB9 female connector. see Table 2.1. J3 - 10 MHz EXT REF INPUT 10 MHz external reference input, 3 ± 3 dBm, 50/75 ohms, BNC (female) connector.
2.4 Installation / Operation 2.4.1 Installing and Operating the 2015-58 Upconverter 1. 2. 3. 4. 5. 6. Connect a -35 dBm to -10 dBm, 70 MHz signal to IF IN, J4 (Figure 2.2) Connect RF OUT, J5, to the external equipment. Connect 100- 240 ±10% VAC, 47 - 63 Hz to AC input on the back panel. Set the desired output frequency (See Section 2.5 Menu Settings). Set the input level (See Section 2.5 Menu Settings). Set the gain for +0 to +30 dB.
2.5 Menu Settings 2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.5): Power Up Normal Display Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Menu 6 Menu 7 Menu 8 Frequency in MHz Input Level in dBm (-30 to -10) Gain in dB (+10.0 to +30.
2.5.2. Power On Settings NOTE: The last status of a unit is retained even when power is removed. When power is restored, the unit will return to it's previous settings. When power is first applied, the LCD display goes through three steps. 1.The LCD goes black to show all segments are functioning. 2.The software version will be displayed. REV 1.00 3.The present frequency, gain, and selected RF output of the upconverter is shown. F = 5950.000 G = +10.
2.5.4 Frequency Changes At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode or scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window. To change the FREQUENCY: 1.Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.
2.5.5 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode.
2.5.5 Alarm Indications An alarm condition for will occur if the local oscillator phase lock loop (PLL) comes out of lock. The Mute LED will light if you select to mute the Tx Signal and the Remote LED will light when you select the Remote mode. ON POWER UP REV 1.00 Power Up NORMAL DISPLAY F = 5950.000 G = +10.0 Normal Display PUSH BUTTON PUSHING MENU/EXECUTE SEQUENCE F = 5950.
CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com PRINTED IN USA 2015-58 Manual_Rev.