Model 1582-71/72 Instruction Manual RF Switch June 2011 Rev. C MODEL 1582 SWITCH SWITCH AUTO CH 1 CH 2 MAN ALM ON- MANUAL ON- ALM REM RESET LINE SELECT LINE SWITCH A 2 CROSS TECHNOLOGIES, INC. POWER SWITCH B AUTO CH 1 1 MODEL 1582 SWITCH AUTO CH 2 CH 1 CH 2 1 2 CROSS TECHNOLOGIES, INC.
INSTRUCTION MANUAL MODEL 1582-71/72 RF Switch TABLE OF CONTENTS Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Characteristics 2.0 Installation 2.1 Mechanical 2.2 Input and Output Signals 2.3 Controls and Indicators 2.4 Operation 2.5 Switch Mode Setup 3.0 Environmental Use Information PAGE 2 3 3 5 6 6 7 7 9 10 11 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc.
MODEL 1582-71/72 RF Switch 1.0 General 1.1 Equipment Description The 1582-71 provides Auto, Manual or Remote relay switching between CH1 and CH2 RF signals. Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable). The logic controls two separate RF switches, X and Y. The 1582-72 has two independent switches. Switching logic can be selected as follows: 1) CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good.
MODEL 1582 SWITCH SWITCH AUTO CH 1 1 CH 2 MAN ALM ON- MANUAL ON- ALM REM RESET LINE SELECT LINE 2 CROSS TECHNOLOGIES, INC. POWER 1582-71 FRONT PANEL SWITCH A SWITCH B AUTO CH 1 MODEL 1582 SWITCH AUTO CH 2 CH 1 CH 2 1 2 CROSS TECHNOLOGIES, INC. MAN ALM ON- MANUAL ON- ALM REM RESET LINE SELECT LINE MAN ALM ON- MANUAL ON- ALM REM RESET LINE SELECT LINE POWER 1582-72 FRONT PANEL AC1 AC2 B1 B B2 A1 A A2 J1 J2 J3 J4 J5 J6 GND 1 J7 14 REAR PANEL FIGURE 1.
1.2 Technical Characteristics TABLE 1.1 1582-71/72 RF Switch Specifications* Switch Characteristics Impedance Type Isolation Switch Time Insertion Loss Configuration 75 , 50 optional Relay > 65 dB, DC to 10 MHz > 50 dB, to 1.0 GHz > 40 dB, to 1.5 GHz 10 milliseconds 1 dB, DC to 1.0 GHz 1.5 dB, to 2.
2.0 Installation 2.1 Mechanical The 1582-71/72 consists of one RF/Controller PCB and one smaller PCB containing the RF inputs and outputs. It is housed in a 1 RU (1.75 inch high) by 12 inch deep chassis. Redundant switching power supplies provide power for the assembly. The 1582-71/72 can be secured to a rack using the 4 holes on the front panel.
2.2 Input and Output Signals - Figure 2.2 shows the input and output connectors on the rear panel. A, B - RF & IF IN/OUT RF & IF Common In/Out for switches A&B. See Table 2.2. J7 - MONITORS and CONTROLS Terminal Strip. See Table 2.1. AC2 AC1 B1 B B2 A1 A A2 J1 J2 J3 J4 J5 J6 GND 1 AC1, AC2 - POWER IN AC inputs for switching power supplies. 100-240 ±10% VAC, 47-60 Hz. 14 J7 A2, B2 - RF & IF IN/OUT RF & IF Back-up In/Out for switches A&B. See Table 2.2.
2.3 Controls and Indicators - The following are the front panel controls and indicators. SWITCH AUTO CH 2 CH 1 MAN ALM ONLINE MANUAL SELECT ON- ALM LINE 1 REM RESET 2 POWER 1582-71 Front Panel SWITCH A SWITCH B AUTO MAN ALM ONLINE AUTO CH 2 CH 1 MANUAL SELECT ON- ALM LINE CH 2 CH 1 REM RESET MAN ALM ONLINE MANUAL SELECT ON- ALM LINE 1 REM RESET 2 POWER 1582-72 Front Panel FIGURE 2.3 1582-71/72 Manual, Rev.
2.3.1 PC Board Settings NOTE: Dot position means jumper goes from pins 1-2; non-dot means jumper goes from pins 2-3 JP1 - 3-pin jumper - 3-pin jumper that works with JP3 In the dotted position when CH1 alarms the 1582-71 will switch to CH2 until CH2 alarms. At this point, if CH1 is still in alarm, the switch will stay on CH2. When the CH1 alarm clears if CH2 is still in alarm, the switch will switch to CH1.
remotely if both channel alarms are clear or both channels are in alarm. The initial channel can also be selected if both channel alarms are clear or both channels are in alarm. S4 positions 1,2,3,4 to OFF - ICS disabled (Minimum Auto switching, Return to Last State Mode) The 1582-71 goes to the last state (CH1 or CH2) it was in when in AUTO after manually or remotely switching and returning to AUTO. Auto switching occurs only if current channel alarms and the other channel is clear.
2.5 Switch Mode Setup The following gives the switch mode settings of the on board controls that can be changed in the field with JP1, JP2, JP3, JP4; S4. ( Figure 2.3). All shown with external alarm = ground. 1) CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm Non-dot JP1, JP3, JP4; Dot - JP2; S4 - ALL TO OFF. 2) Latch to CH2 Mode - Switches from CH1 to CH2 if CH1 alarms and CH2 is good.
3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C.
CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 1582-71/72 Manual, Rev.