Instruction manual

2.0 Installation
2.1 Input/Output Connectors - The following are the input and output connectors.
AC1 AC2
114J7 J6
GND
J5J4J3J1 J2
A1AA2B1B2 B
J7-MONITORS
& CONTROLS
AC1
POWER IN 1
1.5 A FUSE
AC2
POWER IN 2
1.5 A FUSE
J4-
SW A
RF 2
J6-
SW A
RF 1
J5- SW A
SWITCHED
RF
J1 -
SW B
RF 2
J3 -
SW B
RF 1
J2 - SW B
SWITCHED
RF
FIGURE 2.0 1582-70L REAR PANEL
TABLE 2.0 INPUT / OUTPUT CONNECTORS (FIGURE 2.0)
J1, J2, J3, J4, J5, J6 - RF CONNECTORS (FIGURE 2.0)
J7 - MONITORS AND CONTROLS CONNECTOR (FIGURE 2.0)
Function Pin # Description
ALARM 1 IN 13 Ground or Open (selectable by JP2) is Ch 1 alarm.
ALARM 2 IN 14 Ground or Open (selectable by JP2) is Ch 2 alarm.
REMOTE 1 IN 1 When in AUTO, momentary ground on this pin selects Ch 1.
REMOTE 2 IN 2 When in AUTO, momentary ground on this pin selects Ch 2.
REMOTE RESET IN 4 When in LATCH mode, ground resets switch to Ch 1.
MANUAL INDICATION 8 *Open collector output (< 5) to gnd when in Manual mode.
SWITCH 1 MON 11 **Relay closure to J7 pin 6 (<5) when selected RF is Ch 1 RF.
SWITCH 2 MON 12 **Relay closure to J7 pin 6 (<5) when selected RF is Ch 2 RF.
SWITCH MON COMMON 6 Common pin for SWITCH 1, 2 MONITOR
REMOTE MON 9 *Open collector (< 5) to gnd when in REMOTE mode
GROUND 3,7,10 Ground
NO CONNECTION 5 Not connected
*Max voltage able to be connected to this is +20 VDC @ 30ma
**Max voltage to be connected to this is +30 VDC@ 100 ma
AC1, AC2 - POWER IN - Provides AC inputs for dual power supplies.
*NOTE* When the 1582 RF Switch is installed into a system, J7 Pins 13 and 14 (Alarms In) and appropriate
grounds must be interconnected between the primary(s), backup(s) and the 1582 RF Switch for proper switch
function.
1582-70L Manual, Rev. B Page 5 11/05/09