2.2 Input and Output Signals - Figure 2.2 shows the input and output connectors on the rear panel.
AC1
GND
J2 - RF OUTPUT A (COMMON)
SWITCH COMMON RF output.
Type N (female), 50 .
J7 - MONITORS and CONTROLS
Terminal Strip. See Table 2.1.
J1 - RF INPUT A1
SWITCH 1 RF input.
Type N (female), 50 .
AC1 - POWER IN 1
AC input for switching power supply.
100-240 ±10% VAC, 47-60 Hz.
AC2
J7
J1
A1
J2
A
J3
A2
114
AC2 - POWER IN 2
AC input for switching power supply.
100-240 ±10% VAC, 47-60 Hz.
J3 - RF INPUT A2
SWITCH 2 RF input.
Type N (female), 50 .
FIGURE 2.2 1582-650 RF Switch Rear Panel Inputs/Outputs
Table 2.1 J7
Pinouts (Monitors a
n
nd
Table 2.1 J7 Pinouts (Monitors and Controls)
Pin Function Description
1 REMOTE 1 IN When in AUTO, momentary ground on this pin selects CH1
2 REMOTE 2 IN When in AUTO, momentary ground on this pin selects CH2
3 GROUND Ground
4 REMOTE RESET IN When in LATCH mode, ground resets switch to CH1
5 NC Not Connected
6 SWITCH COMMON Common pin for SWITCH 1, 2
7 GROUND Ground
8 MANUAL *Open collector output (< 5) to GND when in MANUAL mode
9 REMOTE *Open collector (< 5) to GND when in REMOTE mode
10 GROUND Ground
11 SWITCH 1 **Relay closure to J7 pin 6 (<5) when CH1 RF is selected
12 SWITCH 2 **Relay closure to J7 pin 6 (<5) when CH2 RF is selected
13 ALARM 1 IN Ground or Open (selectable by JP2) is CH1 alarm
14 ALARM 2 IN Ground or Open (selectable by JP2) is CH2 alarm
* Max voltage to be connected is +20 VDC @ 30mA
** Max voltage to be connected is +30 VDC @ 100mA
*NOTE* When the 1582 RF Switch is installed into a system, J7 Pins 13 and 14 (Alarms In) and
appropriate grounds must be interconnected between the primary(s), backup(s) and the 1582 RF Switch
for proper switch function.
2.3 Controls and Indicators - The following are the front panel controls and indicators.
S1 - SWITCH RESET
Push-button resets switch to CH1 if it is good and
switch is in LATCH mode. Also resets REMOTE
selection to normal AUTO operation.
S3 - MANUAL SELECT
3-position switch manually selects CH1 or CH2 or
puts the unit in AUTO mode (switch position
determined by Alarm and Remote closures).
DS6 - CH1 ONLINE LED
Lights green when CH1 is
selected.
STATUS
ALARM
HISTORY
ALARM
SWITCH
MANUAL
SELECT
CH1
AUTO
CH2
CH2
ONLINE
MANUAL REMOTESWITCH
RESET
CH1
ONLINE
21
21
POWER
21
DS5 - CH2 ONLINE LED
Lights green when CH2 is
selected.
S2 - HISTORY RESET
Push-button resets ALARM
HISTORY LEDs only.
DS3 - MANUAL LED
Lights red when CH1 or
CH2 is manually
selected (using S3).
DS4 - REMOTE LED
Lights yellow when
remote control is active.
DS8,DS7 - ALARM LEDs
Light red when CH1 or CH2
alarm input is a closure or
open (selectable).
DS1,DS2 - ALM HIST LEDs
Light red on CH1,CH2 alarm,
and stay red until HISTORY
RESET is pressed.
DS9,DS10 - POWER LEDs
Light green when power is
applied to AC1, AC2.
HISTORY