Instruction manual

2.0 Installation
2.1 Mechanical - The 1582-14 is rack mounted by attaching the front panel to a rack through the four holes at
the edges of the panel.
2.2 Rear Panel Inputs and Outputs - Figure 2.0 shows the input and output connectors on the rear panel.
AC1
POWER IN 1
1.5 A FUSE
AC2
POWER IN 2
1.5 A FUSE
J6
SWITCH A
DATA 1
J3
SWITCH A
DATA 2
J7
SWITCH A
SWITCHED DATA
J106
SWITCH B
DATA 1
J103
SWITCH B
DATA 2
J107
SWITCH B
SWITCHED
DATA
J8
MONITORS
AND
CONTROLS
AC
1
AC
2
DATA B2 DATA A1
1
J8 J3
GN
D
DATA B1 DATA B DATA A
J7J6J103J107J106
A
DATA A2
B
FIGURE 2.0 1582-14 Rear Panel I/Os
5 4 3 2 1
9 8 7 6
FIGURE 2.1 DB9 Pin-Outs
TABLE 2.0 Rear Panel Input/Output Connectors Pinout
J3, J6, J7, J103, J1066,
J106, J107 - Datta
DATA 3 8 RS422 Levels
GROUND 5 Ground
NO CONNECTION 1 2 4 6 7 9 Not connected
J8 - Monitors and Conttrols
Controls Conne
c
ctor
ALARM 1 IN 13 Ground or Open (selectable by JP2, JP102) gives CH1 alarm
ALARM 2 IN 14 Ground or Open (selectable by JP2, JP102) gives CH2 alarm
REMOTE 1 IN 1 When in AUTO, momentary ground on this pin selects CH1
REMOTE 2 IN 2 When in AUTO, momentary ground on this pin selects CH2
REMOTE RESET IN 4 When in LATCH mode, ground resets switch to CH1, resets REMOTE to AUTO
MANUAL INDICATION* 8 Open collector output (<5) to GND when in MANUAL mode
SWITCH 1 MON** 11 Relay closure to J8 pin 6 (<5) when selected data is CH1 data
SWITCH 2 MON** 12 Relay closure to J8 pin 6 (<5) when selected data is CH2 data
SWITCH MON COMMON 6 Common pin for SWITCH 1, 2 MONITOR
DATA ALARM* 9 Open collector (<5) to GND when clock on CH1 or CH2 is lost
GROUND 3 7 Ground
NO CONNECTION 5 10 15 Not connected
*Max voltage able to be connected to this is +20 VDC @ 30ma.
**Max voltage to be connected to this is +30 VDC @ 100 ma.
1582-14 Manual_A Page 5 06/22/09