Specifications

Specification
Item General Specifications
Dimensions and Mass
Without protector (option 010)
Size: 270 (W) x 165 (H) x 61 (D) mm
Weight: 2.2 kg (4.8 lbs) including battery
With protector (option 010)
Size: 284 (W) x 200 (H) x 77(D) mm
Weight: 2.9 kg (6.4 lbs) including battery
Display 6.5 inch TFT-LCD (640x480, with backlight, transparent type)
Interface USB 1.1, TypeA x1 (memory), Type Bx1 (USB mass storage).
Data Storage
Internal memory: 20 MB (~1000 traces),
External memory (USB): ~30,000 traces with 512 MB
Power Supply
12 VDC,
100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz
Battery
Type: Lithium ion
Operating Time
1
: 8 hours
Recharge Time: <5 hours (power off)
Power Saving Functions
Backlight off: disable/1–99 minutes
Auto shutdown: disable/1–99 minutes
Vertical Scale 0.05, 0.125, 0.25, 0.5, 1.25, 2.5, 5, 6.5 dB/div
IOR Setting 1.000000 - 1.999999 (0.000001steps)
Units km, m, kft, ft, mi
Languages
user selectable (English, French, German and Simplified Chinese - contact Anritsu for avail-
ability of others)
Sampling Points
2
Normal: 5001, High density: 20001 or 25001
Sampling Resolution
3
5 cm (min)
Reflectance Accuracy Single mode: ±2 dB, multimode: ±4 dB
Distance Accuracy ±1 m ±3 x measurement distance x 10
-5
± marker resolution (excluding IOR uncertainty)
Distance Range
Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (except 780 nm: 0.5, 1, 2.5 km)
Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Testing Modes
Fault locate: provides end/break location, end to end loss, fiber length
Standard OTDR: user selectable automatic or manual set-up
Construction OTDR: automated, multi-wavelength testing
4
Light source: stabilized light source (CW, 270 Hz, 1 kHz, 2 kHz output)
Loss test set (optional): power meter and light source
Power Meter
Visual fault locator (optional): visible red light for fiber identification and troubleshooting
Fiber Event Analysis
Auto or manual operation, displayed in table format
User defined PASS/FAIL thresholds:
- reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
- reflectance: 20.0 to 60.0 dB (0.1 dB steps)
- fiber end/break: 1 to 99 dB (1 dB steps)
Number of detected events: up to 99
Macrobend detection
OTDR Trace Format Telcordia universal. SOR, issue 2 (SR-4731)
Other Functions
Real time sweep
5
: 0.15 second
Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL
Averaging modes: timed (1– 3600 seconds)
Live Fiber detect : verifies presence of communication light in optical fiber
Connection check: Automatic check of OTDR to FUT connection quality
Trace overlay and comparison
Environmental Conditions
Operating temperature and humidity: 0 to +40C,<80% (non-condensing)
Storage temperature and humidity: –20 to +60C, <80% (non-condensing)
Vibration: Conforming to MIL-T-28800E Class 3
Dust proof: MIL-T-28800E Class 2
Drip proof: IP51 (IEC 60529), JIS C 0920 TYPE I
EMC EN61326:1997+A1:1998+A2 : 2001+A3:2003 (Class A, Annex A), EN61000-3-2:2000(Class A)
LVD EN61010-1:2001 (Pollution Degree 2)
Notes
1 : Typical, backlight off, sweeping halted at 25˚C, 6 hours typical continuous testing
2 : Either high density value is selected depending on distance range
3 : Except 780 nm
4 : To be planned
5 : Sampling mode normal. Except models 062, 068 -1 second or less
MT9083A ACCESS Master