Specifications

Light Source and Power Meter Specifications Standard on all models
12
Stabilized Light Source
(through OTDR port)
Standard Integrated Power Meter
13
(through OTDR port)
Item Specification Item Specification
Wavelength
14
Same as OTDR Maximum Input +10 dBm
Spectral Width
15
5 nm (1310 nm)
≤10 nm (1490/1550/1625 nm),
3 mn (1650 nm),≤1 nm (1383 nm)
Measurement Range 50 to –5 dBm
Fiber Type Same as OTDR Fiber Type Same as OTDR
Optical Connector Same as OTDR Optical Connector Same as OTDR
Output Power
15
5 ±1.5 dBm Accuracy
18
±6.5%
Output Stability
16
±0.1 dB
Supported Wavelengths
1310, 1550, 1625 nm plus
1490 nm (056, 058, 060)
1383 nm (059)
1650 nm (050, 051, 053, 054, 055, 057, 061)
Modes of Operation
17
CW, 270 Hz, 1 kHz, 2 kHz
Laser Safety Same as OTDR
Features Store reference, loss table
Visible Light Source (Option 002)
Central Wavelength 650 nm ±15 nm (at 25˚C)
Optical Output 0 ±3 dBm (CW)
Output Optical Fiber 10/125 µm, SMF (ITU-T G.652)
Optical Connector 2.5 mm universal
Laser Safety
21
IEC Pub 60825-1Class 3R, 21 CFR1040.10 Excludes deviations caused by conformance to Laser Notice
N.50 (issued 27 May 2001)
Environmental Same as OTDR
Notes
12: Some models do not support built-in light source and power meter
(See next page)
13: If option 003, 004 or 005 is ordered, the standard integrated power meter
is not available
14: Option 059:1383 ±20 m
15: CW, 25˚C
16: CW, 0 to 40˚C (±1˚C) difference between max/min. values over 1 minute,
SM fiber 2 m
17: Modulation +1.5% with 10 minute warm up
18: CW input, –20 dBm At 1550 nm, 23˚C
±
2 Using Master FC connector
19: Peak power, subtract 3 dB for modulated tones
20: +3 to 60 dBm (Option 006 @850 nm)
22: Safety measures for laser products
This option complies with optical safety standards in Class 3R of IEC
60825-1; the following descriptive labels are affixed to the product.
21: CW, model 003: At–10 dBm 1310/ 1550 nm,
At–10 dBm 850 nm 25˚C
model 004/005: At 0dBm 1310 and 1550 nm
Using Master FC connector
Loss Test Set Specifications Optional on all Models
13
Power meters (003, 004, and 005, 006)
Optical Power Meter (Option 003, 004, 005, 006)
12
Option Number MT9083A-003 MT9083A-006 MT9083A-004 MT9083A-005
Fiber Type
Single Mode: 10/125 µm
(G.652),
Multimode: 62.5/125 um
Single Mode: 10/125 µm (G.652),
Multimode: 62.5/125 um
PC only for UPC connector
Single Mode:10/125 um
(G.652)
PC only for UPC connector
Single Mode: 10/125 µm
(G.652)
Measurement Range
19
+3 to –70 dBm
20
+23 to 50 dBm +30 to 43 dBm
Wavelength Range 750 to 1700 nm 1200 to 1700 nm
Calibrated Wavelengths 850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm 1310, 1383, 1490, 1550, 1625, 1650 nm
Optical Connector
Universal uses MA9005B
adapters
Universal uses JXXXX adapters
(same as OTDR)
Universal uses MA9005B
adapters
Accuracy
21
±5%
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Features Store reference, loss table