Instruction manual

1.2 Technical Characteristics
TABLE 1.1 1582-22L RF Switch Specifications*
Switch Characteristics
Impedance 75
Type / Configuration Latching Relay / DPDT
Insertion Loss 2 dB (10 to 25 MHz)
Not Specified (26 MHz to 0.8 GHz)
1.5 dB, 1.0 dB typ. (0.95 to 1.5 GHz)
2.5 dB, 2.0 dB typ. (1.5 to 2.15 GHz)
Frequency Response ±0.5 dB, any 40 MHz BW (0.95 to 2.15 GHz)
Return Loss 12 dB, 14 dB, typ. (0.95 to 1.5 GHz)
10 dB, 12 dB, typ. (1.5 to 2.15 GHz)
Isolation -50 dB (10 to 25 MHz)
-50 dB, -55 dB typ. (0.95 to 2.15 GHz)
Switch Time 20 ms
DC Switching 24VDC @ 2.4 Amps; 48VDC @ 1.8 Amps
Controls
MANUAL SELECT Manually select CH1 or CH2
SWITCH RESET Resets to CH1 in latch mode, and resets REMOTE
HISTORY RESET Resets alarm history (prior occurence of alarms now cleared) - LEDs only
MANUAL SELECT Manually select CH1 or CH2
Indicator LEDs
CH1 ON-LINE Turns green when Channel 1 is selected
CH2 ON-LINE Turns green when Channel 2 is selected
MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2.
ALARM CH1 Turns red when Channel 1 alarm input is a closure or open (selectable)
ALARM CH2 Turns red when Channel 2 alarm input is a closure or open (selectable)
ALARM HISTORY 1 Turns red on Channel 1 alarm and stays red until HISTORY RESET is pushed
ALARM HISTORY 2 Turns red on Channel 2 alarm and stays red until HISTORY RESET is pushed
POWER CH1 Turns green when power is applied to AC1 input on the rear panel
POWER CH2 Turns green when power is applied to AC2 input on the rear panel
REMOTE Turns amber when REMOTE control is active
MANUAL SELECT Manually select CH1 or CH2
Other
Alarm/Control Conn. Terminal Strip
RF Connectors BNC (female), 75 (see Table 2.2 for other options)
Mechanical 19-inch standard 1RU chassis, 1.75”H x 12”D
Power Redundant power supplies; 100-240 ±10% VAC, 47-63 Hz, 30W
*+10˚C to +40˚C; 2000m max elevation; 80% max humidity; Specifications subject to change without notice
1582-22L Manual, Rev. C Page 4 06/13/11