Instruction manual

C) Commands Table 1.2 lists the commands for the 1200-88 and briefly describes them. After a command is
sent the 1200-88 sends a return “>” indicating the command has been received and executed.
General Command Format - The general command format is {aaCND...}, where:
{ = start byte
aa = address (RS-485 only - option Q)
C = 1 character, either C (command) or S (status)
N = 1-digit command or status number, 1 through 9
D = 1 character or more of data (depends on command)
} = stop byte
Table 1.2 1200-88 Comman
d
ds
Commands
Command Syntax* Description
Set GAIN 1 {aaC1xxx} where:
• xxx = 3 characters
• Range: -25 to +25
Set GAIN 2 {aaC2xxx} where:
• xxx = 3 characters
• Range: -25 to +25
Enable Remote # Just # sign
Disable Remote {aaCR0} {CR and zero}
* PLEASE NOTE: The Address (aa) should only be used when RS-485 is selected.
1200-88 Manual, Rev. A Page 6 8/18/10