Technical Manual
Technical Manual  
ARGUS AM Floor System     
Cross Point Device Explorer  v1.2  Page 44 of 65 
13.5.7  Entrances – selected device 
If you click on the ARGUS AM Floor System unit or panel in the 3D-view, some individual 
settings  can  be  configured.  In  the  bottom  part  of  the  screen,  various  buttons  will  be 
available. 
  Scope view 
The  Scope view  screen  shows the  signals  that  are  received  by the  ARGUS  AM Floor 
System. 
Figure 44: Scope view 
The Scope view itself shows the signals that are being detected on the antennas that are 
connected to the ARGUS AM Floor System control unit. 
The red line is the threshold level. The threshold level actually determines the sensitivity of 
the system. A low threshold level creates higher sensitivity, where a high threshold level 
results in lower sensitivity. 
When a signal (blue line) rises above the threshold level (red  line) and other detection 
criteria are met, the alarm will be triggered. 
Never adjust the system too sensitive, as this will result in false alarms!  
Remove any noise sources that interfere with the system or install the 
antennas as far as possible away from noise sources. 