Technical Manual
Technical Manual
ARGUS AM Floor System
Cross Point Device Explorer v1.2 Page 44 of 65
13.5.7 Entrances – selected device
If you click on the ARGUS AM Floor System unit or panel in the 3D-view, some individual
settings can be configured. In the bottom part of the screen, various buttons will be
available.
Scope view
The Scope view screen shows the signals that are received by the ARGUS AM Floor
System.
Figure 44: Scope view
The Scope view itself shows the signals that are being detected on the antennas that are
connected to the ARGUS AM Floor System control unit.
The red line is the threshold level. The threshold level actually determines the sensitivity of
the system. A low threshold level creates higher sensitivity, where a high threshold level
results in lower sensitivity.
When a signal (blue line) rises above the threshold level (red line) and other detection
criteria are met, the alarm will be triggered.
Never adjust the system too sensitive, as this will result in false alarms!
Remove any noise sources that interfere with the system or install the
antennas as far as possible away from noise sources.