Technical Manual
Technical Manual
ARGUS AM Floor System
Configurations v1.2 Page 24 of 65
10.2 Rules for extended configurations
The following rules apply when installing multiple control units and antennas:
• A receiver antenna is always placed at 10 cm distance from a transceiver antenna
when these antennas are connected to the same control unit
• A receiver antenna can be placed at 10 to 35 cm (for DR labels) or 10 to 65 cm (for
OSTRA F25 tags) distance from a transceiver antenna when they are not
connected to the same control unit.
• The minimum distance between two transceiver antennas is 90 cm when they are
not connected to the same control unit.
10.3 Configuration examples for DR labels
Taking the rules as described in section 4 into consideration, the following configurations
can be defined for use with DR labels for various entrance widths.
Figure 13: Basic configuration; 1 control unit + 2 TRx coils – max. 240 cm entrance width
Figure 14: Basic configuration + 1 Rx coil – max. 285 cm entrance width
Figure 15: Basic configuration + 2 Rx coils – 330 cm entrance width
Figure 16: Extended configuration; 2 control units – max. 525 cm entrance width