Technical Manual
Technical Manual RF Mono
Cross Point Device Explorer v1.4 Page 34 of 47
7.7.5 Entrances – selected antenna
If you click on an RFM antenna in the 3D-view, various individual antenna settings can be
configured. The following tabs will appear at the bottom of the screen:
Scope view RF 7.7.5.1
The Scope view RF screen offers oscilloscope views of the signals received by the RFM
antenna.
Figure 27: Scope view RF
This scope view shows the detected signals (black line) as they appear within the
transmission bandwidth (white section). The total bandwidth depends on the “Begin of
sweep” and “End of sweep” settings in the System – RF settings screen (see section
7.8.2).
Views 7.7.5.1.1
By default, the Output scope view is displayed, but also other scope views can be
selected under View. The following scope views are available.
Output (default selected)
Input X
Input Y
Tuning
The X-axis shows the frequency in kHz and the Y-axis shows the signal amplitude.
View output 7.7.5.1.2
The Output scope view shows the detected signals after full digital processing and
filtering. When a tag is presented within the detection range, the signal created by the tag