Technical Manual

Technical Manual RF Mono
Cross Point Device Explorer v1.4 Page 33 of 47
Alarm history 7.7.4.1.6
The Alarm history screen shows a list of tags that have been detected on all antennas in
this entrance.
Figure 26: Alarm history
Dependent of the notification settings, the incoming , outgoing and undefined
alarms can be distinguished by means of their individually colored icons.
By default all types of alarms are displayed, but pressing one or more of the filter buttons
will show or hide the selected alarms.
All alarms are date & time stamped, so it’s easy to find out when they occurred.
It is possible to view the alarm history per day for the last 30 days or to a maximum of
390 alarms per device. Just click the Previous/Next day buttons to scroll through
the alarm history.
Click the Delete button to delete all alarms in the list and to permanently remove them
from all the connected antennas in this entrance.
Antenna alarm threshold 7.7.4.1.7
The antenna alarm threshold value indicates the number of alarms that are accepted by
the retailer to occur each day. If the number of alarms for this entrance exceeds the
configured value, a problem will be generated and will be visible in the Problems
reported section of the dashboard.
The value ‘0’ disables this feature and will never raise a problem. Any other value will,
when exceeded, raise a problem.