Installation guide
install
Leveling
Legs
A
WARNING
Excessive
Weight
Hazard
Use
two
or
more
people
to
move
and
install
dryer.
Failure
to
do
so
can
result
in
back
or
other
injury.
(4
»
Prepare
dryer
for
leveling
legs
To
avoid
damaging
floor,
use
a
large
flat
piece
of
cardboard
from
dryer
carton;
place
under
entire
back
edge
of
dryer.
Firmly
grasp
dryer
body
(not
console
panel)
and
gently
lay
dryer
down
on
cardboard.
(2.
Screw
in
leveling
legs
diamond
marking
~~
Examine
leveling
legs,
find
diamond
marking.
Screw
legs
into
leg
holes
by
hand,
use
a
wrench
to
finish
turning
legs
until
diamond
marking
is
no
longer
visible.
Now
stand
the
dryer
on
its
feet.
Slide
the
dryer
until
it
is
close
to
its
final
location.
Leave
enough
room
for
electrical
connection
and
to
connect
the
exhaust
vent.
Electrical
Connection
Power
Supply
Cord
A
WARNING
Gh)
é
Fire
Hazard
Use
a
new
UL
listed
30
amp
power
supply
cord.
Use
a
UL
listed
strain
relief.
Disconnect
power
before
making
electrical
connections.
Connect
neutral
wire
(white
or
center
wire)
to
center
terminal
(silver).
Ground
wire
(green
or
bare
wire)
must
be
connected
to
green
ground
connector.
Connect
remaining
2
supply
wires
to
remaining
2
terminals
(gold).
Securely
tighten
all
electrical
connections.
Failure
to
do
so
can
result
in
death,
fire,
or
electrical
shock.
Electrical
Connection
Options
(—
1.
Choose
electrical
connection
type
Power
supply
cord
4-wire
receptacle
©
(NEMA
Type
14-30R):
Go
to
steps
1-2
on
]
|
page
9
for
power
supply
cord
strain
relief
then
steps
3-6
for
4-wire
Power
Supply
=]
Cord
Connection
section.
Then,
go
to
Venting
Requirements.
Power
supply
cord
3-wire
receptacle
(NEMA
Type
10-30R):
Go
to
steps
1-2
on
page
9
for
power
supply
cord
strain
relief:
then
steps
3-5
for
3-wire
Power
Supply
Cord
Connection
section.
Then
go
to
Venting
Requirements.
4-wire
direct
connection:
Go
to
steps
1-2
on
page
10
for
direct
wire
strain
relief:
then
steps
3-8
for
4-wire
Direct
Wire
Connection
section.
Then
go
to
Venting
Requirements.
3-wire
direct
connection:
Go
to
steps
1-2
on
page
11
for
direct
wire
strain
relief:
then
steps
3-7
for
3-wire
Direct
Wire
Connection
section.
Then
go
to
Venting
Requirements.
NOTE:
If
local
codes
do
not
permit
connection
of
a
cabinet-ground
conductor
to
neutral
wire,
go
to
“Optional
3-wire
Connection”
section.
This
connection
may
be
used
with
either
a
power
supply
cord
or
a
direct
wire
connection.