Product Manual

2726
Engine Oil Inspecon
Check engine oil when engine is stopped and placed on a level
surface.
1. Rotate the lock 90° counter clockwise, and open right
maintenance door.
2. Remove the oil gauge.
3. Check the oil. If the oil level is below the highest mark, add
the specied oil to the highest mark.
4. Reinstall the oil gauge.
5. Rotate the lock 90° clockwise and close right maintenance
door.
Low oil shut down. If the engine oil is too low, the engine
will automacally shut down to protect the engine. To avoid
unnecessary engine shutdowns, check oil levels regularly.
Engine Oil Replacement
1. Rotate the lock 90° counterclockwise and open right
maintenance door.
2. Remove the black rubber seal ring under the oil drain bolt.
3. A suitable container for oil is placed at the boom of the
engine.
4. Remove the oil gauge.
5. Remove oil drain bolt and washers to drain oil thoroughly.
6. Reinstall the oil drain bolts and washers and ghten the oil
drain bolt.
7. Reinstall the black rubber seal ring.
8. Place the generator on a horizontal surface and add the
specied oil to the maximum scale.
9. Reinstall the oil gauge.
10. Rotate the lock 90° clockwise and close right maintenance
door.
Oil Specicaon Table
Use four-stroke oil.
SAE 10W30 is
recommended for regular
use. However, when the
average temperature in
your area is within the
recommended range, you
can use other viscosity
types of oil shown in the
chart.
Air Filter
1. Rotate the lock 90° counter clockwise, and open le
maintenance door.
2. Loosen the air lter cover clamp and remove the air lter
cover, foam lter core, lter core bracket and paper lter
core together.
3. Paper lter element:
a. Remove the paper lter element from the lter holder.
b. If the paper lter element is dirty, replace it with a new
one. Do not wash the paper lter element.
c. Insert the paper lter element into the lter holder.
4. Foam lter:
a. Remove the foam lter element from the empty lter
cover.
b. Check the foam air lter to make sure that it is clean
and in good condion. If the foam lter element is
dirty, refer to the following page for cleaning. If the
foam lter element is damaged, replace it with a new
one.
5. Put the foam lter element, the lter holder and the paper
lter element together into the empty lter cover.
6. Install the air lter cover and lock the cover clamp.
7. Close the le maintenance door, and rotate the lock 90°
clockwise.