Manual

!
NOTE 1: Applicable types (if available).
!
NOTE 2: Before each season and aer then (whichever
comes rst)
!
NOTE 3: Service more frequently under severe, dusty,
dirty condions.
!
NOTE 4: To be performed by an authorised service
agent.
GENERATOR MAINTENANCE
!
WARNING: DO NOT use water to clean the generator.
Water can enter the generator through the cooling slots
and damage the generator windings.
!
WARNING: DO NOT modify the generator in any way.
DO NOT tamper with governed speed. The generator
supplies the correct rated frequency and voltage when
running at factory sengs.
Tampering with the factory set governor will void your
warranty
Pg. 23
Each
me
before
use
10
Hours
or the
rst
month
(Note
2)
50
Hours
or every
three
months
(Note
2)
100
Hours or
every six
months
(Note 2)
300
hours
or every
year
(Note 4)
Engine oil
Inspecon
Replacement
Air lter
Inspecon
Replacement
(Note 3)
Spark plug
Inspecon and
adjustment
Replacement
Spark
arrester
(Note 1)
Inspecon and
adjustment
Idle speed
Inspecon and
adjustment
(Note 4)
Valve
clearance
(Note 4)