Product Manual
CONNECTING THE HOSES
!
NOTE: DO NOT Operate this pump unl you have read
ALL safety, operaon, and maintenance Instrucons listed
in this manual.
1. Pump connecons - Check you have been provided with
all the following parts (Parts may vary from dierent
models). Connect them as follows;
1.1 Connect the lter to the sucon hose.
!
CAUTION: Ensure that the lter is securely
connected so it can prevent debris being passed
into the pump. Keep the sucon hose at least
200mm below depth ensuring it is fully submerged
and there are no obstrucons.
1.2 Connect the sucon hose to the inlet port
!
CAUTION: It is recommended that the sucon
hose be made of hardened pipe and it is short in
length (7m maximum based on sucon depth).
1.3 Connect the outlet hose to the outlet port
!
CAUTION: The maximum water ow for the
pump is based on rpm, outlet size and hose size.
It is recommended to use a 3” hose for maximum
water ow. Fasten all hoses to the pump so they
cannot loosen under high pressure.
Suction hose
❶ Inlet port
❷ Rubber sealing gasket
❸ Hose tail
❹ Hose nut
❺ Clamp
❻ Sucon hose
Pg. 9
❶ Outlet port
❷ Rubber sealing gasket
❸ Hose tail
❹ Hose nut
❺ Clamp
❻ Outlet pipe