TROUBLE SHOOTING
!
WARNING: Turn o the pump before starng
maintenance work.
FAULT POSSIBLE CAUSE REMEDY
Engine can
hardly start
or cannot
start /Low
power
1. Throle closed
2. Stop switch closed
3. Choke opened
4. Carbon store in spark plug
5. Spark plug and ignion gap
large or small
6. Spark plug damage
7. Inferior oil or fuel is used.
8. Engine works over loaded or
over heated
9. Insucient oil
1. Open the throle governor
2. Turn the switch to ON posion
3. Close the choke
4. Remove the carbon accumulaon
5. Adjust the gap to standard value
6. Change to a new one
7. Change new fuel or oil
8. Check the engine work condion
9. Add oil to standard level
Pump cannot
work or low
water ow
aer engine
start
1. Impuries Filter blocked
2. Insucient water in pump
3. Problem on water pipe like
block, loosen, leak and pipe,
length too long or diameter
too narrow.
4. Input pipe is not in the
water.
5. Input pipe leak
6. Pump mounng too high
7. Engine works low speed
1. Check and remove the impuries
2. Unscrew the rubber plug to ll enough
water
3. Check the water pipe and adjust
4. Check and put it into water
5. Check the connecng
6. Lower the mounng height
7. Turn the throle governor to high
speed
!
NOTE: If a problem is sll exists, contact your local
authorised service agent for advice.
For any quesons regarding operaon or maintenance,
please consult your local service agent. Find your local
service agent at www.crommelins.com.au.
Pg. 22