Product Manual

3. INSUFFICIENT FUEL
Check fuel gauge window on top of generator. If red
mark on side of E (as illustraon), it means insucient
fuel. Refuel generator.
① Fuel gauge window
② Red fuel level mark
③ E—Empty
④ F—Full
4. FUEL SUPPLY BLOCKED
Carburetor blocked.
Stale fuel inside the carburetor will not combust. The
soluon is to loosen carburetor fuel drain screw ①,
turn on FUEL SWITCH to ON posion and let fuel ow
out of the carburetor for 10-20s (collecng it in a tray)
④. If no fuel ows out aer loosening fuel drain screw
in above operaon, it means fuel supply might be
blocked. Consult your local service agent.
6. AIR FLOW BLOCKED
Air lter element blocked. Refer to page 28.
Spark arrestor blocked. Refer to page 31.
7. POOR SPARK
Spark plug is dirty with carbon or wet. Remove
carbon or wipe and dry spark plug. Check spark plug
clearance 0.5~0.7mm. Replace it if there is over
tolerance. Faulty ignion system: Consult the local
service agent.
8. OVERLOADING and generator no
output
Refer to page 15 and LED
Indicators.
Pg. 33