Product Manual
3. INSUFFICIENT FUEL
• Check fuel gauge window on top of generator. If red
mark on side of E (as illustraon), it means insucient
fuel. Refuel generator.
① Fuel gauge window
② Red fuel level mark
③ E—Empty
④ F—Full
4. FUEL SUPPLY BLOCKED
• Carburetor blocked.
Stale fuel inside the carburetor will not combust. The
soluon is to loosen carburetor fuel drain screw ①,
turn on FUEL SWITCH to ON posion and let fuel ow
out of the carburetor for 10-20s (collecng it in a tray)
④. If no fuel ows out aer loosening fuel drain screw
in above operaon, it means fuel supply might be
blocked. Consult your local service agent.
6. AIR FLOW BLOCKED
• Air lter element blocked. Refer to page 28.
• Spark arrestor blocked. Refer to page 31.
7. POOR SPARK
• Spark plug is dirty with carbon or wet. Remove
carbon or wipe and dry spark plug. Check spark plug
clearance 0.5~0.7mm. Replace it if there is over
tolerance. Faulty ignion system: Consult the local
service agent.
8. OVERLOADING and generator no
output
• Refer to page 15 and LED
Indicators.
Pg. 33