Product Manual
PERIODIC MAINTENANCE
It is an owners requirement to periodically inspect, adjust,
lubricate and maintain their generator to keep it in good
working condion.
!
!
Spark Plug
Check condion, clean and replace
if necessary
○
Fuel Check fuel level and leakage
○
Fuel hose
Check fuel hose for cracks or
damage. Replace if necessary.
○
Engine oil
Check oil level in engine
○ ○
Replace
○ (1)
Air lter
element
Check condion and clean
○ (2)
Spark
arrester
element
Check condion, clean and replace
if necessary
○
Fuel lter Clean and replace if necessary
○
Breather
air hose
Check breather hose for cracks or
damage. Replace if necessary.
○
Cylinder
head
De-carbonise combuson chamber,
inlet valve, and exhaust valve of
cylinder head. More frequently if
necessary
●
Valve
clearance
Check and adjust when engine is
cold.
●
Fings/
fasteners
Check all ngs and fasteners.
Correct if necessary.
●
General
inspecon
Check machine over for any
abnormality.
○
- Initial replacement of engine oil is after 1 month or
20 hours of operation.
- When using in unusually wet or dusty areas,
more frequent cleaning is required.
● - Contact your local authorised service agent
to conduct this service