Product Manual
FUEL SWITCH
OFF - Fuel supply o.
ON - Fuel supply on.
ENGINE SWITCH
OFF: Ignion circuit o; generator stops.
ON: Ignion circuit on; generator OK to
START.
ENGINE START BUTTON
When FUEL SWITCH and the ENGINE
SWITCH are both in the ON posion,
press the ENGINE START buon
① Press buon (green) - The
generator will automacally start (aer a few seconds).
REMOTE CONTROL
When the FUEL SWITCH and ENGINE SWITCH are both
in the ON posion, press START ① on the remote
control and the generator will automacally start (aer
a few seconds). Press STOP ② on the remote control to
shutdown.
① START
② STOP
!
NOTE: The remote start distance may be shorter due
to obstacles or baery power reducon. It is suggested to
not exceed 20 metres.
ECO SWITCH
ON: When the ECO SWITCH is ON the
generator runs at idle speed with no load.
When a load is connected, it runs at various
RPMs as per the load, which reduces fuel
consumpon and lowers the noise level.
OFF: The generator will run at its full rated RPM. This
suits equipment that require a high inial output or for
equipment that require high connuous output.
!
NOTE: The ECO SWITCH must be set to OFF for
equipment that require a high starng current. E.g.
Compressor submersible pump.