Product Manual
AIR CLEANER CHECK/CLEAN
A dirty air cleaner will restrict air ow to the combuson
system. To help prevent problems, service the air cleaner
regularly. Service more frequently when operang the
generator in extremely dirty areas.
!
!
CAUTION: Never run the generator without the air
1. Loosen the cover screws and remove the right
maintenance door.
2. Remove the air cleaner case retaining screws. Remove
the case front and check the element. Clean or replace
the element if necessary.
3. Wash the element in a non-ammable or low ash point
solvent and dry it thoroughly.
4. Soak the element in clean engine oil and squeeze out the
excess oil.
5. Reinstall the air lter element and the air cleaner case
front. Tighten the retainer screws securely.
6. Reinstall the right maintenance door and ghten the
screws securely
V
H
z
Kw