DC APPLICATION
You may use the DC receptacle to charge external baeries.
The DC receptacle provides a regulated, polarized 12V, 6A
DC supply. The generator must be running to charge an
external baery through the DC receptacle.
CHARGING EXTERNAL BATTERIES
!
• To prevent the possibility of creang a spark near the
baery, connect the charging cable rst to the baery
being charged, and then to the generator. When
charging is complete, disconnect the cable rst at the
generator.
• Before connecng charging cables to a baery that is
installed in a vehicle, disconnect the vehicle’s ground
baery cable. Reconnect the vehicle's ground baery
cable aer the charging cables are removed. This
procedure will prevent the possibility of a short circuit
and sparks if you make accidental contact between a
baery terminal and the vehicle's frame or body.
• Connect the posive charging cord to the posive
baery terminal. Do not reverse the charging cables, or
serious damage to the generator and/or baery may
occur. Physical injury may also occur.
!
1. Start the generator (Make sure economy switch is in OFF
posion).
2. Connect charging cables to the baery terminals rst.
3. Connect the charging cable to the DC receptacle of the
generator last.