DC APPLICATION
You may use the DC receptacle to charge external baeries.
The DC receptacle provides a regulated, polarized 12V, 6A
DC supply. The generator must be running to charge an
external baery through the DC receptacle.
CHARGING EXTERNAL BATTERIES
!



To prevent the possibility of creang a spark near the
baery, connect the charging cable rst to the baery
being charged, and then to the generator. When
charging is complete, disconnect the cable rst at the
generator.
Before connecng charging cables to a baery that is
installed in a vehicle, disconnect the vehicle’s ground
baery cable. Reconnect the vehicle's ground baery
cable aer the charging cables are removed. This
procedure will prevent the possibility of a short circuit
and sparks if you make accidental contact between a
baery terminal and the vehicle's frame or body.
Connect the posive charging cord to the posive
baery terminal. Do not reverse the charging cables, or
serious damage to the generator and/or baery may
occur. Physical injury may also occur.
!



1. Start the generator (Make sure economy switch is in OFF
posion).
2. Connect charging cables to the baery terminals rst.
3. Connect the charging cable to the DC receptacle of the
generator last.
V
H
z
Kw
