OWNER’S MANUAL 2.
Thank you for purchasing your Cromtech Outback™ 2.4kVA portable petrol inverter generator. This manual provides understanding of the operation and maintenance of this generator. Please read this manual carefully before operating machine. For any questions regarding operation or maintenance, please consult your local service agent. IMPORTANT ICONS Important information is distinguished by the notifications below. The Safety Alarm Symbol ( ! ) alerts you to potential hazards.
INDEX: Warranty ...................................................................... 5 Consumer Advice ........................................................ 5 Crommelins Contact Details ....................................... 5 Important Labels .......................................................... 6 Symbol Meanings ....................................................... 7 Safety Information ....................................................... 8 Highly Flammable and Poisonous Fuel .............
Maintenance ................................................................. 24 Carburetor Adjustment ............................................... 25 Spark Plug Inspection .................................................. 25 Engine Oil Replacement .............................................. 26 Flame Retardant Element and Screen ......................... 27 Air Filter Replacement ................................................. 28 Fuel Tank Filter ....................................................
WARRANTY CROMTECH™ and CROMTECH OUTBACK™ are a registered trademark of Crommelins Machinery. Crommelins Machinery warrants their goods against defects in materials and workmanship under normal use and service. The Crommelins Machinery warranty does not cover fair wear commensurate with the age of the product, any damage caused by accident, abuse, misuse, neglect or failure to observe proper operating instructions or proper machinery maintenance as described in the instruction manual.
LOCATION OF IMPORTANT LABELS ! NOTE: Maintain/replace safety and instruction labels, if worn or illegible when necessary. CTG2500i Series - Safety and instruction labels ① ② ③ ④ Pg.
SYMBOL MEANINGS (Refer to SAFETY INFORMATION for more details. Page 7) ! Attention! Become alert! Your safety is important! Read the manual before operation. Be careful of poisonous exhaust. Never operate the machine in a closed area. Avoid touching hot surfaces, such as engine and muffler. Ground (earth) terminal. Pg.
SAFETY INFORMATION Do not use in a closed vehicle This generator is not designed for marine-use. Do not modify or use the generator with any component removed. Do not allow children to use the generator. Make sure to move the generator only by the carry handle. ① Handle Do not place any obstacle on the generator. Do not place any obstacle in front of exhaust pipe Do not operate generator on wet or dusty/sandy surface. Operate on hard, dry surfaces only.
HIGHLY FLAMMABLE AND POISONOUS FUEL Always stop the engine when refueling. Do not operate, refuel, or store generator near any source of ignition, including fire, heater, grinding sparks etc. Never refuel when smoking or near an open flame. Be careful not to spill any fuel on the Engine or muffler when refueling. Do not swallow, inhale fuel vapor, or allow any fuel into your eye. If this occurs, seek medical attention immediately.
Do not operate the generator in a confined space or when covered with dust cover (or other materials). Ensure the engine and muffler are completely cooled, before covering generator. ELECTRIC SHOCK PREVENTION Never operate generator in rain or snow to avoid electric shock. Never touch the generator with wet hands, or electric shock may occur. ① Ground (earth) terminal Pg.
CONNECTION NOTES Avoid connecting the generator to commercial power socket. Avoid connecting the generator in parallel with any other generator. ① Correct ② Incorrect ! WARNING: Before connecting generator to a building’s electrical system, a licensed electrician must install an isolation (transfer) switch to main fuse box. The switch is the connection point for generator power and allows generator power or main line power to the building.
CTG2500i DIAGRAM ① Vent knob ② Fuel tank cap ③ Fuel tank ④ Handle ⑤ Recoil starter handlebar ⑥ Choke cable ⑦ Control panel ⑧ Muffler ⑨ Main switch ⑩ 12v Charging outlet ⑪ Engine oil cover (Plug) ⑫ Drain screw, carburetor ⑬ Air filter cover ⑭ Spark plug cover CONTROL PANEL ① Choke ② Auto idle switch ③USB Outlets ④ Mains Outlet ⑤ Mains Outlet ⑥ Ground (earth) bolt/nut ⑦ AC Reset ⑧ Low oil alarm ⑨ Over load alarm ⑩ Power indicator ON/OFF SWITCH ① OFF - Ignition circuit and fuel supply are off, and engine st
SMART-THROTTLE SWITCH (ECO-MODE) ① ON - When smart-throttle switch is in ON position, the economic control mode will automatically adjust the engine speed according to the connected load, so as to achieve low fuel consumption and low noise. ② OFF - When smart-throttle switch is in the OFF position, the engine will run at rated speed (5000rpm), regardless of load.
LOW OIL ALARM (YELLOW) If engine oil level falls below the lower level, the low oil alarm will turn on, and the engine will stop automatically. Refill engine oil, otherwise engine will not start. ① Engine Oil Alarm ! NOTE: If engine won’t start, turn the main switch to ON position, then pull the recoil starter. If low oil alarm light flickers for a few seconds, it means engine oil is insufficient. Add engine oil and retry.
4. Restart the engine after checking. ! NOTE: The generator output automatically resets when engine is stopped and then restarted. ! NOTE: The overload indicator light may be ON for a few seconds at first when using electric devices that require a large starting current, such as air conditioner, air compressor, submersible pump, or high-power DC equipment. This is not a malfunction. OUTPUT INDICATOR (GREEN) When the engine is started the output indicator turn ON (Green).
PRE-OPERATION CHECK ! NOTE: Pre-operation checks should be made each time before using generator. FUEL Open fuel tank cap, fill with unleaded fuel to red mark inside fuel filling screen. The recommended fuel is unleaded gasoline #93 octane or above. ! NOTICE: If there is any spilled fuel, use a clean and dry soft cotton cloth to wipe area to avoid corrosion on surface or plastic parts. ! NOTICE: Only use recommened unleaded fuel, as other may cause serious damage on engines inner components.
ENGINE OIL Check the oil level by placing generator on a level surface and inspecting at the oil filter hole. The oil should be level with the Lower edge. Add oil if necessary. ① Lower edge, oil filter hole ! NOTICE: The generator leaves the factory without engine oil. ! NOTICE: Do not tilt the generator when filling engine oil. This may result in overfilling and potential damage to the generator. RECOMMENDED ENGINE OIL A: SAE15W-40 B: SAE10W-30 C: SAE5W-30 ENGINE OIL CAPACITY 300 to 400ml (0.42US qt, 0.
OPERATION INSTRUCTIONS ! WARNING: Always operate generator in a well ventilated area. Never operate generator in a closed in area as it may cause unconsciousness or even death within minutes. ! NOTE: Clean dust, dirt or water off the socket before use. Before starting the engine, do not connect any electrical devices. ! NOTICE: Read PRE-OPERATION CHECK (see page XX) carefully before operation of generator.
2. Turn the main switch to ON position. This turns on the Ignition circuit and allows the fuel to flow. 3. Pull out choke cable button out completely. ① Choke cable button ! NOTE: Choke is not required when starting a warm engine. Set choke back to original position. 4. Pull slowly on the recoil starter handlebar until it is compressing, then pull hard. ! NOTE: Grasp generator by the carry handle firmly to prevent the generator from falling when pulling the recoil starter. 5.
APPLICATION RANGE When using the generator, please make sure total load is under the range of generator rated output, or the generator may be damaged. ! NOTE: The overload alarm indicator ① is on (red) When total watts exceed the application range. (See page 17 for more details.) CTG2500i AC DC Power Factor Rated Output 1.0 2100VA 0.8 1680VA - 96W 12V/8A ! NOTICE: Do not overload. The total load of all electrical appliances must not exceed the supply range of the generator.
AC CONNECTION (POWERING EQUIPMENT) ! WARNING: Be sure all electric devices are turned off before connection. ! NOTICE 1. Be sure all electric devices including lines and plugs connections are in good condition before connecting to generator. 2. Be sure the total load is within generator rated output. 3. Be sure the socket load current is within socket rated current. ! NOTICE: Do not run generator for extended periods with no load or minimal load (eg.
DC OUTLET This generator has a 12 V - 8 Amp DC cigarette style outlet for use with 12V appliances only. We do NOT recommend that this outlet is used for battery charging as it is an unregulated constant output. For battery charging we recommend a 240V battery charger is used as batteries require regulated charge control.
STOPPING THE ENGINE ! NOTE: Disconnect all electric devices. Place smart-throttle switch in position of OFF. 1. Disconnect all electric devices. 2. Turn the main switch to OFF position. 3. Turn the vent knob to OFF position to close vent hole (when engine is completely cooled down). ① Vent knob Pg.
MAINTENANCE It is an owners requirement to periodicly inspect, adjust, lubricate and maintain their generator to keep it in good working condition. ! NOTE: Use only genuine parts for replacement, contact Crommelins spare parts 1300 554 524. ! WARNING: Consult your local service agent for all major maintenance work. ! WARNING: Stop the engine before starting maintenance work.
CARBURETOR ADJUSTMENT Consult your local service agent for any adjustments on the carburetor as special equipment is required for correct adjustment. SPARK PLUG INSPECTION 1. Remove spark plug cover and spark plug cap. ① Spark plug cover ② Spark plug cap 2. Locate spark plug socket on spark plug, turn it clockwise with wrench, and then disassemble spark plug. ③ Spark plug socket ④ Spark plug 3. Check for discoloration and remove the carbon (Standard electrode color: Mediumto-light tan color). 4.
ENGINE OIL REPLACEMENT ! WARNING: Never drain engine oil immediately after turning off engine. Let the engine cool first to avoid scalding. 1. Place generator on a level surface, and start engine for few minutes to reduce the engine oil viscosity. Shut-off the engine, and turn the fuel tank cap vent knob to OFF. 2. Un-screw and remove oil filling cover. ① Screw ② Oil filling cover 3. Remove oil drain plug, place an oil pan under the engine, and tilt the generator to drain the oil completely.
FLAME RETARDANT ELEMENT AND SCREEN ! WARNING: Engine and muffler become very hot when running. Avoid touching the engine and muffler and ensure engine and muffler have cooled before inspecting element and screen. 1. Remove screws on both sides, and disassemble exhaust cover. ① Screw ② Exhaust cover 2. Loosen clamp, and remove flame retardant element locking cap. ③ Clamp ④ Locking cap 3. Use a wire brush to remove carbon deposits frrom flame retardant element and screen.
AIR FILTER REPLACEMENT 1. Loosen screws and remove air intake cover. ① Screw ② Air intake cover 2. Loosen screw, remove air filter cover, and take out filter element. ③ Screw ④ Air filter cover ⑤ Filter element 3. Wash the filter element in solvent and dry it. 4. Add a small ammount of engine oil to element and squeeze out any excess oil. The element should be wet, but not dripping. Recommended filter oil: Foam-air-filter oil or SAE#20 lubricant oil.
FUEL TANK FILTER 1. Open fuel tank cap, and take out inlet filter screen. Remove fuel outlet line and take out fuel outlet filter screen. ① Fuel tank cap ② Fuel filling filter screen ③ Fuel outlet pipe, fuel tank ④ Fuel outlet filter screen 2. Clean the fuel filling filter screen and fuel outlet screen with gasoline. Replace it if damaged. 3. Wipe fuel intake filter screen and outlet filter screen, and install them into fuel tank intake port and outlet port. 4. Install fuel tank cap and tighten it.
2. Low engine oil level: • Add engine oil to specified position. 3. Electrical system • Check main switch, and turn it to position ON. 4. Poor spark • Spark plug is dirty with carbon or wet: Remove carbon or wipe and dry spark plug. • Check spark plug clearance is 0.5~0.7mm: Replace if it is over tolerance. • Faulty ignition system: Consult dealer. GENERATOR HAS NO OUTPUT 1.
STORAGE For long term storage of your machine, follow these preventive procedures to guard against deterioration. DRAIN THE FUEL 1. Remove fuel tank cap. Drain the fuel from fuel tank into an approved gasoline container by a commercially available hand siphon. Then install fuel tank cap. 2. Remove carburetor drain cover, loosen the drain screw on the carburetor float chamber, and drain the fuel from carburetor into an approved gasoline container. ① Drain screw ② Carburetor drain cover 3.
CLEAN THE GENERATOR 1. Clean the exterior part of the generator. Use only damp cloth with mild detergent. Avoid excess moisture. 2. Store the generator in a dry and well-ventilated place, with a clean cloth covered. 3. The generator must remain in a vertical position when stored, carried and operated. TRANSPORT When transporting the generator; 1. Do not overfill the tank (there should be no fuel in the filler neck). 2. Do not operate generator while it is on a vehicle.
WIRING DIAGRAM Pg.
CTG2500i SPECIFICATIONS 2.4kVA CROMTECH™ GENERATOR Max. Wattage 2400watts Cont. Wattage 2100watts Type Single Phase Power Factor 1 Voltage Regulation Inverter / Pure Sine Wave 2.5% THD AC Output 230V - 50hz Cromtech Engine LH148F(G) Engine Type 4 stroke, air-cooled, single cylinder, OHV gasoline engine Displacement 2.6kw, 79cc Engine Oil 300-400ml Fuel Tank 5.
STANDARD FEATURES • Outlets (single phase - 15 Amp) x2 • USB Charging (5V-2 Amp) x2 • Battery charging (12V-8Amp) • Pure Sine Wave <2.5% THD suits precise instruments • Super quiet running at 52-59dbs • Low oil alarm, overload alarm, output indicator • Eco-mode adjusts output as load requires and lowers noise • 5 to 20hrs continuous running (depending on load • Bonus protective yellow cover • 4-Stroke, forced air cooled, OHV engine • 5.