User's Manual

Document
RF Exposure Addition To Integrator's Guide
Page
2(2)
Date
1998-10-23
Rev Document No.
01731-CERT-FCC-SAR-
Integrator's Guide
Copyright 1998, Research In Motion, Limited
RESEARCH IN MOTION
Minimum Separation Distance
For mobile configurations the MPE requirements are met by the minimum passing
distance of 28 cm for Larsen, 3 dB gain ground plane mounted antenna with minimum 6
feet cable length and for Austin, 0 dBd gain ground plane mounted antenna also with
minimum 6 feet cable length, the required distance is 20 cm.
For portable configurations the SAR requirements are met by the passing distance of 8 cm
for The Antenna Company, Eclipse II Magnet Mount, 3 dB gain antenna scaled to zero
cable length.
Operating Manual Compliance Statement
The integrator should include a statement in their operation/user/installation manual
making the user aware of RF exposure issues and insuring that the users keep a passing
distance from the antenna while transmitting.
Also the integrator should provide instructions or diagrams in the manual for proper
antenna mounting and position, when applicable, to ensure a safe exposure distance to the
operator and nearby persons.
Label
If the final device configuration cannot be controlled so as to limit the user distance to the
antenna then the device needs to have an RF radiation hazard label warning the user to
keep away from the antenna by the specified distance.
If the product passes the MPE limit at 20 cm then there is no need for a label on the final
product.
Installation
Any vehicular equipment that integrates R901M and uses a Larsen or Austin antenna will
be required to have the antennas installed at least 28 cm for Larsen and 20 cm for Austin
from any edge of a vehicle rooftop.
It is mandatory for the vehicular application integrators/distributors to add a warning in
their user manual to instruct the installer to mount the antenna at the center of the vehicle
rooftop. As well the instructions should tell the operator/user to maintain the minimum
required distance of 20 cm for Austin and 28 cm for Larsen base mounted antennas at all
times.
For the Antenna Company, Eclipse II Magnet Mount antenna with 3 dB gain, all users are
required to maintain the minimum separation distance of 8 cm from the antenna at all
times. If the final device configuration cannot be controlled so as to limit the user
distance to the antenna by more than 8 cm then the device or the antenna, requires to have
an RF radiation hazard label. This way the users are warned to maintain the minimum 8
cm distance from the antenna.