Specifications
MAGNUM P300 / Jayline CS600
FREESTANDING SPECIFICATIONS
(If installed in accordance with these specifications, the heater complies with ASNZS 2918:2001 including Appendix F)
– Test Report for Magnum P300 07/1655
Magnum P300 Clearance requirements with sin
gle skin stainless 1200mm flue shield
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
150
250
300
200
50
336
614.5
440
1129
976
1270
1140
640
735
729
526
166
367
562
Dimension “C” is taken from front of ash lip to front edge of floor
protector. All dimensions are in millimetres & are set as a
“minimum” in accordance with test report 07/1655 under ASNZS
2918:2001.
R
Wetback Option:
Rural Only
Floor Protector: Non Insulated
Estimated Peak Output (kW): 18kW
Tested Average Output (kW): 8.5 kW
(on 3 pieces (4kg) wood)
Magnum P300
/ Jayline CS600
Outer Dimensions
100 Neilson Street, Onehunga, Auckland, New Zealand
Tel: 09 634 1483 Fax: 09 634 6804
Page 1
Effective October 2007