Specifications

MAGNUM P300 / Jayline CS600
FREESTANDING SPECIFICATIONS
(If installed in accordance with these specifications, the heater complies with ASNZS 2918:2001 including Appendix F)
Test Report for Magnum P300 07/1655
Magnum P300 Clearance requirements with sin
gle skin stainless 1200mm flue shield
A
B
C
D
E
F
G
H
J
K
M
N
P
Q
R
S
T
U
150
250
300
200
50
336
614.5
440
1129
976
1270
1140
640
735
729
526
166
367
562
Dimension C is taken from front of ash lip to front edge of floor
protector. All dimensions are in millimetres & are set as a
minimum in accordance with test report 07/1655 under ASNZS
2918:2001.
R
Wetback Option:
Rural Only
Floor Protector: Non Insulated
Estimated Peak Output (kW): 18kW
Tested Average Output (kW): 8.5 kW
(on 3 pieces (4kg) wood)
Magnum P300
/ Jayline CS600
Outer Dimensions
100 Neilson Street, Onehunga, Auckland, New Zealand
Tel: 09 634 1483 Fax: 09 634 6804
Page 1