Firmware
Check the Crestron website to find the latest firmware. (New users must register to
obtain access to certain areas of the site, including the FTP site.)
Upgrade TPMC-V12/15 firmware via Crestron Toolbox.
1. Establish communication with the TPMC-V12/15 and display the “System
Info” window.
2. Select Functions > Firmware… to upgrade the TPMC-V12/15 firmware.
NOTE: Projects and firmware can also be loaded via a USB flash drive or MMC
drive.
Program Checks
Actions that can be performed on the TPMC-V12/15 vary depending on whether it is
connected via Cresnet or Ethernet.
Cresnet Connections
For Cresnet connections, using Crestron Toolbox, display the network device tree
(Tools > Network Device Tree View) to show all network devices connected to the
control system. Right-click on the TPMC-V12/15 to display actions that can be
performed on the TPMC-V12/15.
Ethernet Connections
For Ethernet connections, using Crestron Toolbox, display the “System Info window
(Tools > System Info) and select the Functions menu to display actions that can be
performed on the TPMC-V12/15.
Be sure to use Crestron Toolbox to create the TPMC-V12/15 IP table.
1. Select Functions > IP Table Setup.
2. Add, modify or delete entries in the IP table. The TPMC-V12/15 can have
only one IP table entry.
3. A defined IP table can be saved to a file or sent to the device.
Edit the control system’s IP table to include an entry for the TPMC-V12/15. The
entry should list the TPMC-V12/15’s IP ID (specified on the TPMC-V12/15’s IP
table) and the internal gateway IP address 127.0.0.1.
Restore
The restore console command restores the TPMC-V12/15 to its original factory
default settings and also restores the original version of the firmware.
NOTE: Use of the restore console command requires all service packs to be
re-installed as well.