Specifications
Universal Presentation Processor Crestron UPX-2
NOTE: The UPX-2 Ethernet default communication mode is DHCP. Refer
to “Ethernet” on page 46 for Ethernet setup instructions and use the SETUP
MENU to change communication format if desired.
4. Ensure that all devices are connected to the control system. For TCP/IP, use
CAT5 straight through cables with 8-pin RJ-45 connectors to connect the
LAN port on the UPX-2 and the LAN port on the PC to the Ethernet hub.
Alternatively, you can use a CAT5 crossover cable to connect the two LAN
ports directly, without using a hub. The following figure illustrates pinouts
for straight through and crossover RJ-45 cables. Pins 4, 5, 7, and 8 are not
used.
RJ-45 Straight Through Cable – For Connection Through Hub
FROM
PIN
COLOR SIGNAL TO PIN SIGNAL
1 White/Orange Tx+ 1 Tx+
2 Orange Tx- 2 Tx-
3 White/Green Rc+ 3 Rc+
6 Green Rc- 6 Rc-
RJ-45 Crossover Cable – For Direct PC Connection
FROM
PIN
COLOR SIGNAL TO PIN
SIGNAL
1 White/Orange Rc+ 3 Tx+
2 Orange Rc- 6 Tx-
3 White/Green Tx+ 1 Rc+
6 Green Tx- 2 Rc-
5. Once the cable connections are made, open Crestron Toolbox and click
Tools | Manage Address book to display the “Address Book” window.
6. Click Add Entry and type a name for the new device.
7. Click TCP as the connection type. Enter the IP address or hostname of the
UPX-2 and click OK.
“Address Book” Window – TCP/IP Setup
Operations Guide – DOC. 6276B Universal Presentation Processor: UPX-2 ¥ 65