Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mounted Touchpanel Operations Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2003 Crestron Electronics, Inc.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Contents 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications ...........................................................................................................
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L Introduction Features and Functions The TPS-2000L, compact video touchpanel, is a 5-inch (12.7-cm) active matrix color display panel with 320 x 234 resolution and 16-bit non-palette graphics. The purpose of this unit is to provide a single, compact touchpanel that ends the age of walls cluttered with switches, control panels, thermostats, etc.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel formats. The unit has a single video input and can display multiple windows when using a third party display splitter. A light sensor brightens or dims automatically with changing room light conditions for easy viewing. The result is an outstanding picture ideal for watching TV, previewing DVDs or checking security cameras. An optional water-resistant cover provides protection around damp rooms such as the pool or spa.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Specifications for the TPS-2000L Touchpanel (Continued) SPECIFICATION DETAILS Video Audio • Balanced (CAT5) video (via CNX-PVID or CNX-RMCLV device) or unbalanced composite video input through 8-position mini connector (1 Vpp).
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L 2. Crestron 2-Series control systems include the AV2, CP2, CP2E, MP2, MP2E, PAC2, PRO2, and RACK2. 3. CNX update files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX update files have a UPZ extension and ST-CP files are in one EXE or zipped UPZ file. To avoid program problems, make certain you are using the update file with the correct suffix letter (e.g., S, V, W, X). 4.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Physical Views of TPS-2000L Touchpanel 3.07 in (7.79 cm) 3.43 in (8.71 cm) 6.73 in (17.10 cm) 4.76 in (12.10 cm) The TPS-2000L touchpanel has 10 engraveable hard buttons (real buttons, not simulated buttons on the touchpanel membrane), that allow easy access to the most common functions such as lights, volume, drapes, and screen controls with the added benefits of touchpanel flexibility incorporated right into one panel.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L NOTE: These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference received, including interference that may cause undesired operation.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel NOTE: For larger networks (i.e., greater than 28 network devices), it may become necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality throughout the network. Also, for networks with lengthy cable runs, it may be necessary to add a Hub/Repeater after only 20 devices. Identity Code Every equipment and user interface within the network requires a unique Cresnet identity code (Cresnet ID).
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L calibration error by touching the screen in an area that is opposite from the instructed area. Setup Menu SETUP MENU To obtain the SETUP MENU, shown to the left, press the Setup button from the MAIN MENU. The SETUP MENU offers a series of buttons, which opens additional menus and displays, which are detailed in subsequent paragraphs. After setup parameters have been set, select the Return button to return to the MAIN MENU.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Audio Setup Details AUDIO MENU BUTTON* AUDIO SETUP SCREEN DESCRIPTION** Master Volume The volume of all audio types (WAV, line, and key click) is rectified by Master Volume. If Master Volume is set to 100%, the volume value for a given audio type is its full value. If Master Volume is set to 0%, the volume of all audio types is overridden and the touchpanel is silent.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L Video Setup Details VIDEO SCREEN BUTTONS DESCRIPTION* Brightness This button allows for an increase (UP button) and decrease (DOWN button) in the video image brightness. Contrast Saturation Hue This button allows for an increase (UP button) and decrease (DOWN button) in the video image contrast. This button allows for an increase (UP button) and decrease (DOWN button) in the video image saturation.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel If the CURRENT VALUE has exceeded the THRESHOLD VALUE, the screen switches to high brightness. When the CURRENT VALUE is less than the THRESHOLD VALUE, the screen switches to low brightness. ORIENTATION SCREEN SETTINGS ORIENTATION There is no ‘top’ or ‘bottom’ when installing the TPS-2000L. Press the Orientation button to open the SCREEN SETTINGS – ORIENTATION display, shown to the left.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L Timeout Menu TIMEOUT SETTINGS The touchpanel display can be turned off (standby mode) when not in active use. Select the Timeout button on the SETUP MENU to reveal the TIMEOUT SETTINGS display, shown to the left. This setting turns the display off when the touchpanel is inactive for a specified time. Touch the screen to awaken the touchpanel and the last screen to be displayed reappears.
Crestron Isys TPS-2000L 8-PIN CONNECTOR (Top View) 1 2 3 4 5 6 7 8 5 Inch Lectern/Wall Mount Touchpanel The 8-pin connector on the unit provides balanced/unbalanced audio and video (supporting both NTSC/PAL formats). Refer to the pinout after this paragraph for details. The left most columns provide a signal name for each pin. For a balanced audio/video system refer to the BALANCED AUDIO & VIDEO column centered in the table.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Mounting Options for the TPS-2000L PRE-CONSTRUCTION* POST-CONSTRUCTION** OPTION OPTION MODEL NUMBER DOCUMENT NUMBER Back Box Kit Pre-Construction Mount Kit Mud Mount Kit (accessory) - BB-2000L PMK-2000L MMK-2000L 5973 6018 6025 Trim Mount Kit (accessory) - TMK-2000L 6026 - Wall Mount Kit - Mud Wall Mount Kit - Trim Water Resistant Cover WMKM-2000L WMKT-2000L TPS-WPK 6025 6026 5993 * Pre-construction refers to framed walls prior t
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Exploded View for Mounting the TPS-2000L in the Optional BB-2000L Back Box BB-2000L TPS-2000L #6-32 x 112" (SR-06-32-1R5000-2) PAN HEAD SCREW, QTY. 4 SUPPLIED BY CRESTRON The stylish, elegant design accommodates painting and custom laser engraving of its faceplate and keys. There are even plastic faceplates that accept metal and non-metal inlays for that custom contemporary appearance.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L 3. Loosen and remove four screws that secure touchpanel to mounting option. 4. Using equal pressure, carefully remove the touchpanel from the opening. 5. If necessary, secure attached cables before disconnecting them from the back of the touchpanel. Recommended Cleaning Keep the surface of the touchscreen free of dirt, dust, or other materials that could degrade optical properties.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel • VisionTools Pro-e version 2.4 or later. Used for graphical touchscreen design. • Crestron Engraver 2.0.0.9 or later. NOTE: The TPS-2000L touchpanel is supplied with 10 blank pushbuttons. Optional custom engraved keys can be ordered separately by using the Crestron Engraver Software. Version 2.0.0.9 or later is available from the Downloads | Software Updates section of the Crestron website (www.crestron.com).
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L PRO2 System View The System Views lower pane displays the PRO2 system tree. This tree can be expanded to display and configure the communications ports. Expanded PRO2 System Tree C2Net-Device Slot in Configuration Manager To incorporate the TPS-2000L touchpanel into the system, drag the TPS-2000 from the Touchpanels | Touchpanels (Cresnet) folder of the Device Library and drop it in the System Views.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel “Device Settings” Window for the TPS-2000L NOTE: SIMPL Windows automatically changes NET ID values of a device added to a program if a duplicate device or a device with the same default NET ID already exists in the program. Always ensure that the hardware and software settings of the NET ID match. For NET ID hardware settings details, refer to “Interface Menu” on page 8.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L In SIMPL Windows, the signal types are color-coded as follows: Digital = Blue Analog = Red Serial = Black Undefined/Other = Green NOTE: “Other” signals are a combination of the three basic types (e.g. many symbols accept either analog or serial signals where the combination is shown as a green signal). The signal type is displayed on the Status Bar when the signal is highlighted. For additional information, refer to Doc.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Digital Output Signal Descriptions OUTPUT DESCRIPTION press 1 through press 4000 Notifies control system of button press (1 - 4000). High/1 = Button being pressed Low/0 = Button not being pressed Digital Input Signal Descriptions INPUT DESCRIPTION fb 1 through fb 4000 Notifies panel of button press (1 - 4000). This can represent that the button was pressed, or can be an actual device feedback, e.g., that power was turned on.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L touchpanel uses the programmed project until another set is uploaded from the PC. The PC may be disconnected from the rack or panel except during reprogramming. VT Pro-e also allows users the option to generate projects destined for web browsers rather than for physical touchpanels. For additional software information, refer to the help file provided with the software.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Crestron VT Pro-e (version 2.1.0 and later) contains an audio tool, Sound Manager, which permits the panel designer to attach WAV files to a touchpanel project. Sound Manager is available from the Tools pull-down menu and opens the “Sound Manager” window, shown after this paragraph. “Sound Manager” Window Sound Manager Guidelines There are three things to keep in mind when using Sound Manager. Operations Guide – DOC. 5972A 1.
5 Inch Lectern/Wall Mount Touchpanel c. Crestron Isys TPS-2000L Mute Key Click – The keyclick sound is muted when this join number goes high. NOTE: If a join number is not assigned (“NONE”) for an Audio parameter, then the audio parameter is enabled. Using Sound Manager Sound Manager is broken into two distinct components. The Project Audio Joins component, shown below, permits the designer to assign the three system-wide join numbers described in the previous section.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel 4. Repeat steps 1 through 3 for each desired WAV file. NOTE: To remove a WAV file from the Sound List table, highlight the file and click on the Remove button. The Properties button opens the “Sound Properties” window for a highlighted WAV file in the Sound List table. The designer can assign a join number either automatically with the Auto button or by scrolling down to the desired number.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L 11. On the same page, create a button. The button can be located anywhere on the page. 12. Access the “Button Properties” window and complete the items in steps 13 through 16. 13. From the Text tab, assign the Text Entry (i.e., Toggle Zoom). 14. From the Select Properties field, select Digital Feedback Join. 15. Enter 17125 into the join number field.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel NOTE: Reserved join numbers can also be automatically activated by a control system when using join number remapping. Contact Crestron Customer Service for more information.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Audio Digital Reserved Join Numbers for TPS-2000L Touchpanels JOIN NUMBER FUNCTION VALUE DIRECTION 17300 Audio On I/O 17301 Audio Off I/O 17302 Key Click On I/O 17303 Key Click Off I/O 17304 Key Click Volume Up I 17305 Key Click Volume Down I 17306 Line Audio On I/O 17307 Line Audio Off I/O 17308 Line Audio Volume Up I 17309 Line Audio Volume Down I 17312 WAV Audio On I/O 17313 WAV Audio Off I
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel MultiByte International Characters Most languages use a single byte of 8 bits to represent a character, e.g. English, French, German, Hebrew, Russian, Thai, etc. Multibyte character fonts require more than the usual 8 bits to specify a character. This occurs when a language has more than 256 characters (28) in a font. For example, Chinese fonts contain several thousand characters. Other multibyte languages include Japanese and Korean.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Communication Settings Connection of a PC to the TPS-2000L touchpanel is provided through a control system (Cresnet). To prepare the TPS-2000L for uploading or upgrading, refer to the following figure for a typical connection diagram. NOTE: For laptops and other PCs without a built-in RS-232 port, Crestron recommends the use of PCMCIA cards, rather than USB-to-serial adapters.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Setup | Communications Settings Command 4. Select RS-232 as the connection type. Verify that an available COM port (COM 1 is shown after this step) is selected, and that all communication parameters and necessary options from the “Port Settings” window are selected as shown after this step. Click the OK button to save the settings and close the window.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L NOTE: Control system communications can be verified by selecting Diagnostics | Establish Communications (Find Rack). This should display a window that gives the COM port and baud rate. If communication cannot be established, refer to the “Troubleshooting Communications” section in the respective Operations Guide for the control system. Uploading a SIMPL Windows Program A control system source file has the extension .smw.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel “Send Program” Window 4. To verify that the program has been transferred successfully, select Diagnostics | Report Program Information or press F7. This should display a window that provides details about the current program loaded into the control system. Uploading a VT Pro-e Project The TPS-2000L touchpanel source file has the extension .vtp. A compiled VT Pro-e file has the extension .vtz.
5 Inch Lectern/Wall Mount Touchpanel 3. Crestron Isys TPS-2000L As shown after this step, select the NET ID of the TPS-2000L touchpanel and then click OK. The “Touch Panel Transfer” window appears (refer to the subsequent graphic). “Select Network ID” Window NOTE: When transferring any Cresnet file (touchpanel project/firmware), lower the port speed baud rate to 38400 to match the Cresnet bus speed when transferring through a control system.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel “Open” Window 5. Select the VT Pro-e (vtz) file and click Open. The transfer will complete automatically. Firmware Upgrade A firmware upgrade file has the extension .csf. To take advantage of all the TPS-2000L features, it is important that the unit contains the latest firmware available. Therefore, please check the Crestron website (http://www.crestron.com/downloads/software_updates.asp) for the latest version of firmware.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L “Select Network ID” Window NOTE: When transferring any Cresnet file (touchpanel project/firmware), lower the port speed baud rate to 38400 to match the Cresnet bus speed when transferring through a control system. Select CSF File 4. Browse to the .csf file and click Open to begin the transfer. 36 • 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L Operations Guide – DOC.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Problem Solving Troubleshooting The table after this paragraph provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-2000L Touchpanel Troubleshooting TROUBLE POSSIBLE CAUSE(S) Touchpanel does not function. Touchpanel is not communicating with the network. Use Performance Viewport (via SIMPL Windows or VT Pro-e) to poll the network.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions, please take advantage of the Crestron award winning customer service team by calling: • In the US and Canada, call the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. • In Europe, call Crestron International at +32-15-50-99-50. • In Asia, call Crestron Asia at +852-2341-2016.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. (“Crestron”) for software referenced in this guide, which includes computer software and, as applicable, associated media, printed materials, and “online” or electronic documentation (the “Software”).
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Crestron of its authorized agent.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
5 Inch Lectern/Wall Mount Touchpanel Crestron Isys TPS-2000L This page intentionally left blank. 42 • 5 Inch Lectern/Wall Mount Touchpanel: TPS-2000L Operations Guide – DOC.
Crestron Isys TPS-2000L 5 Inch Lectern/Wall Mount Touchpanel This page intentionally left blank. Operations Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 5972A 01.03 Specifications subject to change without notice.