Specifications
Isys
™
Wired 5.7 Inch Tabletop Touchpanel Crestron TPS-1700
2 • Isys
™
Wired 5.7 Inch Tabletop Touchpanel: TPS-1700 Operations Guide - DOC. 6117
Specifications
The table below provides a summary of specifications for the TPS-1700.
Specifications of the TPS-1700 Touchpanel
SPECIFICATION DETAILS
Power Requirements 10 Watts, 24 VDC, 0.40 Amp
Default NET ID 03
Default Standby Timeout 10 minutes
Signal Join Maximums 4K (digital), 4K (analog), 999 (serial)
Control System Update Files
1, 2, 3
2-Series Control System Update
CEN/CN-TVAV Update File
CNMSX-AV/Pro Update File
CNRACKX/-DP Update File
ST-CP Update File
Version C2-2004.CUZ or later
Version 5.13.12V.UPZ or later
Version 5.12.63X.UPZ or later
Version 5.10.11W.UPZ or later
Version 4.02.04S.UPZ or later
Acceptable File Extensions
4
SIMPL Windows
.smw
.spz
.bin
.csz
VT Pro-e
.vtp
.vtz
Firmware
.csf
projectname.smw (source file)
projectname.spz (compiled file for 2-Series)
projectname.bin (compiled file for CNX generation)
projectname.csz
(compiled file for CNX generation with SIMPL+)
projectname.vtp (source file)
projectname.vtz (compiled file)
TPS-1700xxxxxx.csf (panel firmware)
Memory 4 MB flash memory (3.5 Mbytes available
for user programming)
8 MB SDRAM
Touchscreen Dimensions Height: 3.50 in (8.89 cm)
Width: 4.60 in (11.68 cm)
Diagonal: 5.70 in (14.48 cm)
Touchscreen Angles ±50° for X dir, +40/-50° for Y dir
Touchscreen Resolution 320 x 240 pixels, 64K colors (16 bit)
Touchscreen LCD Active matrix
Touchscreen Illumination Backlit fluorescent
Touchscreen Composition Resistive Membrane
Operating Temperature 50° to 113°F (10° to 45°C)
Humidity 10% to 90% RH (non-condensing)
Overall Dimensions Width: 8.75 in (22.23 cm)
Height: 3.62 in (9.20 cm)
Depth: 5.43 in (13.80 cm)
Weight 1.85 lb (0.84 kg)
1. The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com)
. Refer to NOTE after last footnote.
2. Crestron 2-Series control systems include the AV2, PAC2, PRO2, and RACK2.
3. CNX update files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX
update files have a UPZ extension and are in one EXE or zipped UPZ file. To avoid program problems,
make certain you are using the update file with the correct suffix letter (e.g., S, V, W, X).
4. Extension requires a prefix specific to the touchpanel type. In DETAILS, projectname represents the
assigned project name, and xxxxxx represents a version number.