Specifications
Tilt Touchpanels Crestron Isys
®
TPS-12/15/17
Toolbox Functions Menu – Specific to TPS-12/15/17
NOTE: The list of functions depends on the type of device.
TCP/IP Communication
This section explains how to configure a TPS-12/15/17 to communicate over
Ethernet using TCP/IP. These procedures assume that the touchpanel has been
powered up and connected properly.
PC-to-touchpanel communications can be implemented over TCP/IP as shown in the
following diagram. TCP/IP is the fastest method of communicating between the PC
and the touchpanel.
Typical Connection Diagram when Uploading a Touchpanel Project or Firmware to the
Touchpanel via TCP/IP
1. To establish TCP/IP communications with the touchpanel, a serial
connection must be established between the PC and touchpanel. Refer to
“Indirect Serial Communication” on page 43 or “Direct Serial Connection”
on page 46 for instructions.
2. While connected to the touchpanel, select Functions | Ethernet
Addressing. The current IP address, IP mask and default router are
displayed.
¥ Tilt Touchpanels: TPS-12/15/17 Operations Guide – DOC. 6375
48