Specifications

Crestron SWAMP(I)-24X8 Sonnex Multiroom Audio System
Operations Guide DOC. 7049D Sonnex Multiroom Audio System: SWAMP(I)-24X8
41
Uploading and Upgrading
Crestron recommends using the latest programming software and that each device
contains the latest firmware to take advantage of the most recently released features.
However, before attempting to upload or upgrade it is necessary to establish
communication. Once communication has been established, files (for example,
programs or firmware) can be transferred to the control system (and/or device).
Finally, program checks can be performed (such as changing the device ID or
creating an IP table) to ensure proper functioning.
NOTE: Crestron software and any files on the website are for authorized Crestron
dealers and Crestron Service Providers (CSPs) only. New users must register to
obtain access to certain areas of the site (including the FTP site).
Establishing Communication
Use Crestron Toolbox for communicating with the SWAMP-24X8; refer to the
Crestron Toolbox help file for details. There are three methods of communication:
indirect, USB, and TCP/IP.
Indirect
Indirect Communication
PC Running
Crestron Toolbox
Serial,
or USB
LAN
Cresnet
Control
System
COMPUTER
PWR
NET
HW-R
SW-R ACQUIRE ACTIVITY
SWAMP-24X8
SWAMP-24X8 connects to control system via Cresnet:
1. Click Tools | System Info.
2. Click the
icon.
3. For Connection Type, select Indirect.
4. For Device is at, select Cresnet ID and select the ID number from the drop-
down menu.
5. In the Through drop-down menu, select the control system.
NOTE: If no address book entry is listed for the control system, click
Address Book… to create an entry. For details, refer to the Crestron
Toolbox help file.
6. Click OK. Communications are confirmed when the device information is
displayed.