Specifications
Crestron e-control Vote SW-VOTE
121 •• Appendices Installation & Reference Guide — DOC. 5822
Status
s
Voting Console
Description
Individual seat status
Direction
Voting Computer to control system
Type
Analog
Value
0 ....... ABSENT
1 ....... PRESENT
2 ....... YES
3 ....... NO
4 ....... ABSTAIN
5 ....... EXCUSED
6 ....... HIDDEN (while floor is opened during a “secret” ballot)
Expected Reply
None
Comments
These signals issued when
§ signal block first enabled (all set to PRESENT);
§ attendance aborted or vote aborted or concluded (set to ABSENT or PRESENT as
determined by last attendance);
§ seat’s status changes during a vote in response to its Yes, No, and Abstain
signals; or
§ seat’s status changes after a vote in response to Operator editing the vote either by
using the Voting Computer interface (via mouse-clicks or contextual menu
selections on seat icons), or from the control system (by issuing a Change signal).
These signals are generally tield directly to an touchpanel animated object.
These signals are only valid after a vote when the floor is closed, including after
displaying the vote results (while either StateEnd or StateDisplay is high). Ignored
if issued at the wrong time.
See Also Change