Specifications
Crestron e-control Vote SW-VOTE
119 •• Appendices Installation & Reference Guide — DOC. 5822
StatePrintSave Voting Console
Description
Vote is being recorded
Direction
Voting Computer to control system
Type
Digital
Value
Assert: Results now being recorded on Voting Computer
([Print &] Save Results button feedback ON)
De-assert: Results have been recorded
([Print &] Save Results button feedback OFF)
Expected Reply
To an assert: None
To a de-assert: None
Comments
Results are saved either
§ by user interaction with the Vote Proctor window on the Voting Computer:
[Print &] Save Results button (which is only enabled after a vote); or
§ when control system issues the PrintSave signal after a vote.
The signal is de-asserted when the Voting Computer finishes recording the vote
The de-assert is always followed by the following (in the order given):
§ All “state” signals are de-asserted
§ NewVote pulse
§ All digital “tally” signals are de-asserted and analog “tally” signals are reset to 0
§ All Change
s
signals are reset to either 0 (absent) or 1 (present)
§ Agenda scroller (if there is one) is requeried to eliminate the just-voted-upon item
(which may or may not cause signals to be sent to alter the display)
§ AgendaEcho with the value “[Vote concluded]”
Used in conjunction with the other “state” signals, StateStart, StateEnd, and
StateDisplay; and the pulsed signals, NewVote and AgendaTrigger. These
signals provide feedback to the control system about the voting sequence. They
can be used to highlight the sequence control buttons, or to enable/disable
touchpanel choices. (See “State Coordination,” page 61, for a “score sheet”
illustrating the sequence.)
See Also PrintSave, AgendaEcho, NewVote