StateEnd Voting Console
Description
Voting concluded
Direction
Voting Computer to control system
Type
Digital
Value
Assert: Voting concluded, console ready to display or print/save
(End Vote button feedback ON)
De-assert: Results displayed or printed/saved
(End Vote button feedback OFF)
Expected Reply To an assert: Display, PrintSave, or Abort
To a de-assert: None
Comments
Voting can be concluded either
§ by user interaction with the Vote Proctor window on the Voting Computer: End Vote
button (only enabled while the floor is opened); or
§ when control system issues the End signal when the floor is opened.
End vote feedback goes dark when:
§ User interaction with the Vote Proctor window on the Voting Computer: Display
Results or [Print &] Save Results button (both of which are only enabled after a
vote); or the Abort button (enabled during and after a vote);
§ control system issues the Display signal; or
§ control system issues the PrintSave signal.
Used in conjunction with the other “state” signals, StateStart, StateDisplay, and
StatePrintSave; and the pulsed signals, NewVote and AgendaTrigger. These
signals provide feedback to the control system about the voting sequence. They
can be used to highlight the sequence control buttons, or to enable/disable
touchpanel choices. (See “State Coordination,” page 61, for a “score sheet”
illustrating the sequence.)
See Also End, Display, PrintSave, Abort