Specifications
Crestron e-control Vote SW-VOTE
117 •• Appendices Installation & Reference Guide — DOC. 5822
StateDisplay Voting Console
Description
Results on display
Direction
Voting Computer to control system
Type
Digital
Value
Assert: Results now displayed on Voting Computer and/or need to be
displayed on some device connected to control system
(Display Results button feedback ON)
De-assert: Results display down
(Display Results button feedback OFF)
Expected Reply To an assert: Display (again), PrintSave, or Abort
To a de-assert: None
Comments
Results can be displayed either
§ by user interaction with the Vote Proctor window on the Voting Computer:
Display Results button (which is only enabled after a vote); or
§ when control system issues the Display signal after a vote.
The signal is de-asserted when:
§ the Voting Computer’s Vote Results window looses the focus (is closed or partially
or totally obscured by some other window):
§ user interaction with the Vote Proctor window on the Voting Computer: Abort
button (only enabled during and after a vote); or
§ control system issues the Display signal (again, presumably after the vote has
been edited by the operator);
§ control system issues the PrintSave signal; or
§ control system issues the Abort signal; or
Even though the Display Results button feedback remains high, the button may
be used to update the display when, for example, the operator has edited a vote
using either the Voting Computer interface (via mouse-clicks or contextual menu
selections on seat icons); or from the control system (by issuing Change signals).
Used in conjunction with the other “state” signals, StateStart, StateEnd, and
StatePrintSave; and the pulsed signals, NewVote and AgendaTrigger. These
signals provide feedback to the control system about the voting sequence. They
can be used to highlight the sequence control buttons, or to enable/disable
touchpanel choices. (See “State Coordination,” page 61, for a “score sheet”
illustrating the sequence.)
See Also