User manual

DCS 6000 Digital Conference System User Manual
50
19” brackets for installing in 19” standard racks
USB memory stick with ‘User Manual’
PS CU Power Supply
Main Voltage .. 100-240V, 50-60 Hz nominal
Max. consumption .................................. 175 W
Total supply power .... 144W (power factor: >0.9)
Input current ................. max. 4A@115V AC
................. max. 2A@230V AC
In-rush current .................... max. 40A@115V
................... max. 80A@230V
Standby consumption ............... <0,5W (no load)
Supply voltage for CU ........... 48V/3A @ 40 deg C
(De-rate linearly to 50% @ 60 deg C)
Efficiency typical ................................ 87%
Weight .............................. 935 g
Dimensions (W x H x D) ............ 99 x 52 x 180 mm
Approvals ... CE, KC, CCC, cULus, TÜV
Specifications are subject to change without
notice.
Connection Details
Mains
Blue Neutral
Brown Live
Green/Yellow Earth (Ground)
DCS-LAN Chain
The DCS 6000 system uses shielded Cat5e, Cat6
or Cat7 F/UTP or U/FTP cables with shielded RJ45
connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
New name
FTP
F/UTP
STP
U/FTP
UTP
U/UTP
Important: Use only F/UTP or U/FTP (shielded) cables
and shielded RJ45 connectors and not U/UTP cable,
which are unshielded.
How to wire a Cat5e (EIA 568-B) cable to a RJ45
con.:
Pin
Function
Connector #1
Connector #2
1
In-going +
ORG/WHT
ORG/WHT
2
In-going -
ORG
ORG
3
+48V
GRN/WHT
GRN/WHT
4
0V
BLU
BLU
5
0V
BLU/WHT
BLU/WHT
6
+48V
GRN
GRN
7
Outgoing -
BRN/WHT
BRN/WHT
8
Outgoing +
BRN
BRN
Important: If other color codes are used then the
four pairs are connected as follows:
Pair 2: Pin 1 & 2
Pair 3: Pin 3 & 6
Pair 1: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in Cat5e (EIA 568-B)
have to be followed.
Note: Cat6 and Cat7 cables can normally only be
terminated in sockets (female) and not in cable
plugs.
Cat6 and Cat7 can thus only be used for feeding
cables terminating in wall outlets or patch panels.
Analog Audio Out
XLR3 male
Pin
Signal
Cable type
1
Earth
2 x 0.25 mm2
shielded.
2
Signal +
3
Signal
Analog Audio In
XLR3 female
Pin
Signal
Cable type
1
Earth
2 x 0.25 mm2
shielded.
2
Signal +
3
Signal
Emergency switch