User manual

DCS 6000 Digital Conference System User Manual
15
connection to the built in web application or for
connection to SW 6000 or a control system like
AMX® or Crestron®.
4. Audio output A, B, C & D Four male XLR3
connectors for connection of PA systems, Audio
Mixers, Audio Recorders or Language
Distribution System etc
5. Audio input In 1 & In 2 Two female XLR3
connectors for extra audio inputs. ‘In 1’ and ‘In
2’ is used to connect auxiliary symmetrical
audio signals such as a wireless microphone to
the floor language.
‘In 2’ is also used for connection of an
Emergency Evacuation Message (EEM)
audio signal.
6. Emergency switch connector A
terminal block socket for a single, ‘normally
open’ switch. When the switch is closed, the
audio signal on the ‘In 2’ connector is
distributed on all output channels and
loudspeakers, overriding all other audio
inputs.
Note: There is no volume control available for setting
the EEM volume on ‘In 2’. The volume has to be set
at the equipment generating the “Emergency
Evacuation Message (EEM)” audio signal.
Simplified Audio Schematic
Figure 0-A CU 6105 Central Unit Audio Schematic