LookupParm
n
Applies to
e-Mailer signal blocks
Description
Sets a particular text substitution register
Direction
system-to-server
Type
Analog
Value
A number matching the contents of the ID field of a record in the eMail_Msg table
of the database file specified in the e-Mailer signal block definition. The substitution
field from the matching record is set as the value for substitution parameter n.
Expected Reply
None
Comments
Definition of these signals is optional.
These signals provide new values for the same substitution parameters affected by
the SetParm signals.
See additional comments under SetParm.
See Also
For more information on how substitution parameters are utilized, refer to “Text
Substitution and File Inclusion” on page 48.