Specifications

Crestron e-control Mail SW-MAIL
34 Server Configuration In Depth Installation & Reference Guide — Doc. 5798
The e-Mailbox Signal Block Definition window, showing the definition of DEMO4, the e-mailbox signal
block used in demo4, with the e-Mail account information frame filled in, and the Process control
messages option checked.
NOTE: The domain name part of the Mailbox name is set for all e-mailbox signal blocks under the
e-Mail tab in the Configuration Options window (see “POP3 Server URL Field” on page 24).
Mailbox Name and Password
The Mailbox name is an account name established on the e-mail host. The password
is the password for that account. It is required of all active e-mailbox signal blocks.
If missing from any such signal block, the server protocol cannot be started.
Optional signal definitions
This frame lists optional signals which can be excluded from the signal block (and
from the congruent Intersystem Communications symbol on the control system
side). For further information on each of the optional signals listed in this frame,
refer to the “Signal Reference” on page 68. To exclude a (group of) signal(s) from
the signal block, either uncheck its checkbox or enter a zero (or blank) into its
textbox.
Control Messages
Check the Process control messages option if you want the server to check for
control messages and issue these signals. If checked, also specify here the number of
control signals to define in each signal category (Analog, Serial, and Digital). See
Control Messages” on page 49 for more information about control messages.
Using “Receive e-Mail” SIMPL symbol
This option is a convenience feature. Checking it forces the selection of optional
signals to conform to the Receive e-Mail SIMPL symbol (used in place of an