Specifications
1-Way Wireless RF Touchpanels Crestron ST-1550 & ST-1550C
Leading Specifications
The table below provides a summary of leading specifications for the touchpanels.
Leading Specifications of the ST-1550 & ST-1550C Touchpanels
SPECIFICATION DETAILS
Power Options
ST-BTP (or equivalent)
AC: Domestic External Adapter
AC: International External Adapter
ST-DS
Rechargeable NiCad battery pack (included)
(Fully charged, 2800 mAh capacity. Operating time
depends on usage.)
1
12VDC, 1.5A, 120VAC Input (included)
(P/N PW-1215 or equivalent)
12VDC, 1.5A, 230VAC Input (included with
international version touchpanel)
(P/N PWI-1215 or equivalent)
Docking Station/charger with external power pack
(included)
Default NET ID 3
Default RF ID 10
Default Timeouts 1 minute for standby
2 minutes for power down
Control System Update Files
2, 3, 4
2-Series Control System Update
CEN/CN-TVAV Update File
CNMSX-AV/Pro Update File
CNRACKX/-DP Update File
ST-CP Update File
Version C2-1001.CUZ or later
Version 5.10.13V.UPZ or later
Version 5.10.11X.UPZ or later
Version 5.10.11W.UPZ or later
Version 4.01.04S.UPZ or later
RF Specifications 1-Way Wireless RF Touchpanel, 433.92 MHz
5
Dimensions Width: 8.75 in (22.23 cm)
Height: 5.70 in (14.48 cm)
Depth: 3.33 in (8.45 cm)
Weight (without battery pack) 1.85 lb (0.84 kg)
Memory 1 MByte flash memory
(768 Kbytes available for user programming)
Touchscreen Dimensions Height: 3.550 in (9.017 cm)
Width: 4.700 in (11.938 cm)
Touchscreen Resolution 320 x 240 pixels, 256 colors
Touchscreen LCD STN color, dot matrix type for ST-1550C
FSTN Transmissive mode, dot matrix type for
ST-1550
Touchscreen Illumination Backlit fluorescent
Touchscreen Composition Resistive Membrane
1. Battery life is 180 minutes continuous usage with background lighting at full brightness. Actual
operating time depends on usage and settings for background brightness and timeouts.
2. The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (www.crestron.com)
. Refer to NOTE after last footnote.
3. Crestron 2-Series control systems include the AV2 with CAGE2, PAC2, PRO2, and RACK2.
4. CNX update files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX
update files have a UPZ extension and ST-CP files are in one EXE or zipped UPZ file. To avoid
program problems, make certain you are using the update file with the correct suffix letter (e.g., S, V,
W, X).
5. Requires Crestron CNRFGWA 1-Way RF Receiver, or ST-CP SmarTouch Control Processor.
NOTE: Crestron software and any files on the website are for Authorized Crestron
dealers only. New users may be required to register to obtain access to certain areas
of the site (including the FTP site).
2 • 1-Way Wireless RF Touchpanels: ST-1550 & ST-1550C Operations Guide – DOC. 5803A