System information
Fixed help links for various Ethernet devices.
Fixes/Changes from 2.00.28 to 2.01.00:
Fix compilation of CNXIR-8 cards in a 2 Series control system when using a CNXIR One Way Serial Driver (would
give an "Unknown Device" error in the viewport). This is fixed in library 144 or later.
Fix compilation error when a SMW program name had ( or ) in it, and it contained SIMPL+ (2 Series only).
SIMPL+: Fix issue with SIMPL+ target compilation. If a module is developed & compiled for both 2 and X series, and
used in a 2 Series program, after compilation of the 2 Series program, the module would no longer be available for
use with an X series system until it was compiled for the X target in the SIMPL+ GUI.
Fixes/Changes from 2.00.25 to 2.00.28
Fix problem with modules in a program being reassigned to other modules when Duplicate modules existed in both
User and Project directories.
Fix problem with Module Hint being cleared sometimes.
Fix problem where certain macros would cause the SIMPL Windows compiler to crash (macros that were
programmed with the [~UNUSED~] signal name in order to create gaps)
Fixed problem where TPS Join Number Remap projects would crash the SIMPL Windows compiler if serial strings
were used.
Viewport TPS Transfers: Fix 20 second timeout problem when reading a TPS directory - this would occur when
transferring larger projects to a TPS panel.
Viewport TPS Transfers: Speed improvements
Viewport TPS Transfers: Fix problem where if the size of the files needed to be sent is less than the total capacity
of the panel, the files would be sent even if the total project size wouldn't fit in the panel.
Fixes/Changes from 2.00.24 to 2.00.25
Fix problem with Application Builder generated programs - when opening the SMW file in SIMPL Windows, there
was potential to get a "User Lock" error.
Fixes/Changes from 2.00.23 to 2.00.24 (2.00.24: Internal Release Only)
In prior versions, opening a SIMPL+ module from SIMPL Windows (right click on the module in your program and
choose "Edit User Module") or a SIMPL module (right click on the module in your program and choose "Edit User
Module" and then "In New Instance") and saving the file (with your original program still open in the first instance of
SIMPL Windows) would sometimes cause the modules within your main program to get randomly reassigned as
other modules. This has been fixed.
Fixed problem with Search/Replace not working: When the search and/or replace strings were single digit numbers,
they were being turned into underscores.
SIMPL+: Fix for 2 Series system crashing when an out of bounds array write was performed. The 2 Series system
will now issue an error message about the out of bounds array.
Fixes/Changes from 2.00.22 to 2.00.23 (2.00.23: Internal Release Only)
Fix so that uninstalling or running this version (or later) of SIMPL Windows will not affect uninstalling or running
older versions of SIMPL Windows (or vice-versa).
Allow 0's on the outputs of a JK Flip Flop (2 Series only).
SIMPL Windows compiler: Fix COM ports so that if TX$ or RX$ is left out and signals are put on the transmit or
receive side of the com port (for triggering or matching data that is coded directly into the parameters of the port), it
will trigger or match properly. (2 Series Only).
Fixes/Changes from 2.00.18 to 2.00.22