System information

AFORCE, ACAST), Serial Force (Speedkeys: SFORCE, SCAST), and Digital Force (Speedkeys: DFORCE,
DCAST). These symbols can be placed in a program and connected to a signal to force the type. For example, if
an analog+serial output of an Intersystem Communications (XSIG) symbol is run to analog+serial input of another
Intersystem communications symbol, the ambiguous warning will be produced. The signal can be tied to an "Analog
Force" (or "Serial Force", depending on what type the programmer wanted it to be) to resolve the issue. The Force
symbols have no impact on the final program that is transferred to the rack; they are used on to help resolve
save/compile time ambiguities. These symbols can be used inside of a Macro (.UMC) or in a SIMPL Windows
program (.SMW). (2 Series Only; Present in Library files 155 and later.)
Fix ST-LT compilation (2 Series only).
Fixes/Changes from 2.01.04 to 2.01.05 - PUBLIC FTP SITE RELEASE:
SIMPL+: Fix resource problem between the X Generation and 2 Series compilers.
Fix autofill issue - sometimes autofill will report errors that certain devices did not autofill correctly even though the
actually did.
Fix replace control system issue where serial ports would get moved to incorrect positions.
Fixes/Changes from 2.01.03 to 2.01.04:
SIMPL+: Fix problem with Remove() requiring the last parameter. The last parameter is now optional, as
documented.
Fix driver drop problem with CNX-FZ & CPC-CAMI (fix is also present in Library files 150 and later).
Viewport: Fix problems transferring to a TPS panel through a control system (introduced in v2.66 of the viewport)
Fix autofill problem - CNWMBG2-34 would not properly autofill.
Fixes/Changes from 2.01.02 to 2.01.03:
Fix missing symbol for e-Datalog
Fix problem where Application Builder would not launch (due to changes in 2.01.02 install)
Move LC-3000 from "Discontinued" back to "Touchpanels"
Rename "Obsolete" as "Discontinued" in Configuration Manager's Device Library.
Fixed issue where the "Help" option in the SIMPL+ GUI did not bring up the help system.
Fixed TPS Join Number Remap project to allow 127 Serial Inputs/999 Serial outputs on both the TPS Cresnet and
TPS Ethernet interfaces.
Fixes/Changes from 2.01.01 to 2.01.02:
Fix issue with 2.01.00's fix for SIMPL+ target compilation. (Third item on 2.01.00's fix list).
Fix problems with copying to a similar symbol when converting a control system.
Fixed LiveUpdate for proper version number checking.
Correct compilation of 1 Way Serial drivers on CNXIR-8 cards on 2 Series systems.
Fixes/Changes from 2.01.00 to 2.01.01:
Fixed problem where Simpl+ modules within User Modules were replaced whenever a SAVE AS was performed.
Clear All Watch Signals in SIMPL Windows now clears the status window in Test Manager (if it's opened) and clears
out the last status window information from the .tm file (if it exists).
Viewport: Speed up Initialize time for each file in an SPZ during a program transfer (Requires CUZ 1.010 or later; 2
Series Only)
Viewport: Restrict TCP/IP Console password to 14 characters for compatability with 2-series (previously was limited
to 30 chars)
Viewport: Remove file name length limit for web page transfers for 2-Series control systems (Limit is 66 chars for
CNXENET+)
Viewport: Programs that sent data to the console (i.e. TEST symbols, print() statements, etc.) would sometimes
interfere with uploading a new program. This has been fixed.
Added racktypes CP2, CP2E (library 144 or later) - requires CUZ 1.010 or later.