System information
Ethernet Intersystem Communication device before an Export operation, as this will be needed for the 2 systems to
communicate. Importing a Remote System Definition is an available option on the Program menu. Selecting to
Import a Remote System Defintion will prompt the user for the .rsd file to import, a Prefix that will be prepended to
all the signals read in from the .rsd file and whether the user wishes to override any other device that may be
located at the IP ID defined in the .rsd file. The import process will then first add an Ethernet Intersystem
Communication device to the IP ID defined in the .rsd file and set the IP Address to the IP Address that is also
defined in the .rsd file. Once the Ethernet Intersystem Communication device is added at the appropriate IP ID,
Simpl Windows will then read the signal information from the given .rsd file. An import of a Remote System
Definition will result in all INPUT SIGNALS from the exported Ethernet Intersystem Communication device being
imported as OUTPUT SIGNALs and visa versa.
Fixed compilation issue where buttons didn't press on a Pro2's front panel, but buttons in the same position on a
Pro's front panel would work.
Fixed issue where CNIRHT-15 transmitters would not work on a Pro2 (Also available in library update 179 and
later).
Fixed crash on compilation if a macro file had no logic that could be compiled (i.e. everything commented out, etc.)
Added CTRL-G (Goto) in the SIMPL+ GUI to allow the user to jump to a line number.
SIMPL+: Fix for Bit() and Byte() functions to check the indexed position specified in the function against the current
length of the string, rather than the maximum length.
Fixes/Changes from 2.03.02 to 2.03.03:
Fixed problem with Autofill failing on a MSX-PRO when connection to rack is via ethernet.
Changed the "Search/Replace/F9" function to default to SELECTED when the user has selected 1 or a group of
signals to do a string replace on. If the user selects at the Symbol level (i.e. selection of symbol in the Program
Tree), the setting will still default to ALL.
Fixed problem with Power Supply devices having their Net ID showing up as 01 instead of NONE. Also fixed problem
where the user was being allowed to change the Net ID of a Power Supply. This is no longer allowed.
Fixed problem with deleting control entry devices that take up more than 1 slot.
Added logic to force an Imported CMC module's symbol tree to MISC if there is no category assigned in the original
.CMC file.
Test Manager: Optimization so that large programs will no longer cause test manager to take a long time to start
up.
When transferring a program from SIMPL Windows to a 2 Series processor, the standard viewport dialog will come
up asking whether or not you want to transfer the project to compact or internal flash.
Add more device topics to help file.
Fixed problem where copying a project symbol from one instance of SIMPL Windows to another program in another
instance of SIMPL Windows was causing SIMPL Windows to crash.
Correct compilation of CNX-MIDI card in 2 Series systems. This also requires CUZ 2.009 or later in the 2 Series
processor.
Fixes/Changes from 2.03.01 to 2.03.02:
Viewport: Fix for a problem where accessing the IP info of a CP2E would could cause an access violation on the PC
Viewport: Fix for a problem introduced in 2.84 where having AutoBaudRate on would actually lose the found baud
rate setting, rather than store it
Viewport: Improved reliability of communication with the MT-500C touchpanel
Viewport: Improved support of cancelling a TPS upload in the early stages
Added Import Archive Program to the Opening Dialog.
SIMPL+: Don't allow ReadStructure and WriteStructure within expressions or assignments (2 Series Only).
SIMPL+: ReadStructure and WriteStructure no longer have a return value. Instead, an optional third argument is
allowed to passed into the function that will contain either the total number of bytes read or written, or if negative, a
return error code. (2 Series Only).
SIMPL+: Fixed LONG_INTEGER format specifiers in Print() and MakeString() (2 Series Only).
SIMPL+: Allow x-generation compiler directive functions to compile correctly
SIMPL+: Fixed local variables within Wait Statements (2 Series Only)
SIMPL+: Fixed __FN_DST_STR__ string overflows with STRING_OUTPUTs (2 Series Only)
Fixes/Changes from 2.03.00 to 2.03.01:
Fixed potential problems with Test Manager crashing. This would only happen in 2.03.00; it would not affect