System information
and the device is not added.
Updated processing for PDF help files (help via the Device Library AND the Help Menu->Control CD Product
Directory) to now look for and bring up the product manuals from the Product Catalog CD. Note: Help menu option
is now "Product Catalog CD". Updated the configuration dialogs to now only show available Port/IR/RF/Card ID's
that are valid for the currently selected device. Prior to this, all IDs were being shown even if it may not have been
valid.
SIMPL+: Added and fixed SendMail return error codes
SIMPL+: Force a Rebuild All if the SIMPL+ module
�
s .ush file does not exist.
SIMPL+: Fixed an issue where if a module was set to 2 and X generation, and it was saved and compiled, then
saved, the proper target control systems would not be saved properly with the module.
Viewport: Transfers of VTPro-e 2.4+ generated web pages to ENET+ cards works - no longer uploads duplicate
_CONFIG_INI_.
Viewport: Web page transfers generally more reliable in error conditions.
Viewport: Web page transfers of files greater than 750KB to ENET+ devices now prohibited by software.
Viewport: Fixed problem where opening e-Control 2 activation dialog with no connection would cause a crash.
Viewport: E-Control Activation dialog now checks if control system supports e-Control 2 before opening.
Viewport: Added Help/Help Contents and Help/About to user menu.
Fixes/Changes from 2.03.10 to 2.03.11:
Device Extenders now work when placed on CPC-CAMIs/CNXFZ Cresnet devices. Programs must be recompiled for
the Device Extenders on CPC-CAMI's/CNXFZ Cresnet devices to function. This is a 2 Series only issue. However,
no CUZ change is needed.
Added ability to open AutoSave files (.ASV). The selected .asv file will be renamed to it's .smw file name. User will
be asked if they wish to allow the Rename and proceed.
Provided support for entering Chinese/Japanese/Korean literals in a symbol's parameter field if the
Chinese/Japanese/Korean version of Windows is running. Even though the characters can be entered, a seperate
step to post-process the serial strings will be required before sending the text to a touch panel (multi-byte fonts
need to have their bytes swapped before being sent).
Added ability to refresh a remote system definition file (.RSD) to a different IP ID than the original import may have
been imported to.
Provided an option on the Copy Program dialog for sending the zipped file to the control system mailbox.
Updated the Copy Program feature to now include any VT-PROe project files (.VTP) in the .zip file/directory copy.
When an archive is imported, any .VTP files in the archive will be extracted to the project directory.
Added an option on the UI Project device configuration dialog to allow the user to say whether or not to inherit the
Join assignments from the selected .VTP file into the associated panel.
Fixed problem where SIMPL Windows was allowing carriage returns and/or linefeeds to be a part of a Device Name
which was causing data integrity errors the next time the program was opened.
Viewport: Wait cursor used more appropriately during busy sequences.
Viewport: "Send Default IP Table" dialog no longer appears when program being AutoSent.
Fix "Analog Comparison (Full Set)" so that only the desired outputs may be filled in. Previous versions required all
outputs to be filled in.
Fixed problem where SIMPL Windows might crash when trying to cut and paste symbols in the program tree.
Fixes/Changes from 2.03.09 to 2.03.10:
Fixed problem with compiling program that have Crestron SIMPL+ modules that are only valid on 2-Series systems.
Prevent a SIMPL Windows Program to be opened if the minimum SIMPL Windows version required by that program
is newer than the version trying to open the program. In the past, an error was reported in the error log, but the
program was still being opened. This was causing data integrity errors.
Remote System Definition 'Auto-Refresh' implemented: There is now an option on the Import Remote System
Definition dialog (available via the Project menu or the context menus in the Program Tree and Detail View
windows) that will allow the user to indicate that they would like SIMPL to check for a newer version of the imported
.rsd file. - This option is stored, along with the refresh options (i.e. what to do when signals in the .RSD file have
been deleted/changed) for each Imported Ethernet Intersystem Communication (EISC) symbol. When a program is
opened, SIMPL will look at the value of the AutoRefresh flag for each imported EISC. If the flag is set and a newer
RSD file exists, the user will be then prompted as to whether or not they wish to continue with a refresh of the EISC
data.
Viewport: Fix upload issues to ST-1700 and TPS-2000 panels.
Expose MT-500C & CNRFGWA-418 model for the MT-500C.