System information

SIMPL Windows: Removed display of "Logic Node Commented Out" warning message every time a program with a
TPS Series Panel as the control system is opened. When the control system is added the first time, the Logic Node
is commented out and the user is given the Warning message. However, Simpl Windows will no longer display that
message each time the program is opened.
SIMPL Windows: Fixed problem where, if Simpl Windows was not full screen size and then minimized, and the open
program was then modifed by some other process (such as another instance of Simpl Windows), the minimized icon
could never be restored if the user answered NO to the message box that asked if the program should be
reloaded.
Viewport: Fixed bug where WINS would not be enabled or recognized properly in Configure IP dialog.
Viewport: Added support for SSL
Viewport: Fixed bug in Identify Transmitter ID where any hex digits ('a' - 'f') were not converted properly so it would
give an incorrect transmitter ID.
Viewport: Fixed bug in updating firmware to a DVP4 where the "MESSAGE" command was incorrectly being sent
after the system rebooted.
Viewport: Fixed bug in IP table config. This would give a warning when closing the ip table dialog after adding any
entries to an empty table.
Viewport: Fixed bug in CNX-ENET card update.
Viewport: Added "STOPPROGRAM" and "PROGRESET" commands when configuring a CNXTA card to ensure
reliable communications.
Viewport: Fix problem in exit pass-through function. This was causing problems becuase the viewport tried to find
the control system, but since it was in pass-through it wouldn't be found.
Viewport: Added support for the TPS-RFGWX with band selection capabilities. Reworked the channel / band / low
power selection dialog to detect the capabilities of the gateway and verifiy the settings were actually set correctly.
SIMPL Windows: Change CLW-SW/SWS/DIM/DIMS to require CUZ 3.053 or later (Also available in Library Update
234 and later).
SIMPL Windows: Add support for STX-1700CXP, QM-RMC, *C2N-IADS, *C2N-IVDS, *C2N-NPA8 (Also available in
Library Update 234 and later). Note that items marked with "*" do not currently have help available.
SIMPL Windows: Correct issue with CHV-TSTAT/THSTAT Basic Symbol where the following inputs would not
function correctly: FRONT_PANEL_LOCKOUT, OUTDOOR_TEMP, OUTDOOR_HUM, INDOOR_HUM, and correct
issue where the following outputs would not function correctly: REGULATION_HUMID_F, OUTDOOR_HUMID_F.
The Advanced symbol has no issues. (Also available in Library Update 234 and later).
SIMPL Windows: Add Volume feedback for the C2N-VEQ4 General Audio Controls. If you have an existing program
and wish to gain access to the new feedback outputs, you will have to perform a ReSync Program in SIMPL
Windows. (Also available in Library Update 234 and later.)
Fixes/Changes from 2.04.12 to 2.04.13:
SIMPL Windows: Fixed problem with handling of a Serial Poll Accelerator in a replace control system operation.
SIMPL Windows: Fixed problem with getting "TIO: File opened for write" error when doing a File->Save if have more
than 2 other instances of Simpl Windows open and all with 'Untitled' modules.
SIMPL Windows: Fixed problem with Rename Signal function not working properly.
SIMPL Windows: Added support in compiler for new QM-RMC device (TIO support still pending).
SIMPL Windows: Fixed problem where adding a Prefix to a set of selected signals was also adding the prefix to the
reserved signals "0", "1", and "Local".
SIMPL Windows: Correct long-standing compiler issue where percentages w/out a leading 0 before the decimal
point (i.e. ".1%") would not convert properly.
Fixes/Changes from 2.04.11 to 2.04.12:
SIMPL Windows: Add Poll Manager to CHV-TSTAT/THSTAT Thermostats (also available in Library Update 222 and
later).
SIMPL Windows: Fixed Live Update to not show the "Updates Available" on every start of Simpl Windows when
there really weren't updates available.
SIMPL Windows: Fixed problem with Replace Control System not copying over device locations.
SIMPL Windows: Fixed problem with Replace Control System not copying over bookmarks with Device Symbols
correcltly.
SIMPL Windows: Fixed problem with SIMPL Windows crashing if too many errors are added to the error log. Since it
is possible for tens of thousands of notices/warnings to be generated during a compile as a result of undriven
signals and/or signals without destinations, Simpl Windows now limits the amount of errors to be shown and puts up
a message in the error log that there are more errors that could not be shown (fix existing issues and recompile). It
should be noted that certain warnings/notices can be turned off in Edit -> Preferences (i.e. don't display signals
without destinations, etc.).