System information

SIMPL Windows: Fixed problem with user database not allowing .IR files with names longer than 50 characters.
SIMPL Windows: Fixed SIMPL Windows crash when trying to add a device to a program using the System Tree
(either via Drag/Drop or right click and select Add/Replace Device menu option).
SIMPL Windows: Updated Device Library and Symbol Library folder names for better clarification of where SIMPL
Windows is getting it's data (i.e. from a Library Update file versus the Crestron Database install). The "Device
Library" node in the Device Library tree will now read "Crestron Devices (CresLib xxx). The "Logic Symbols" node in
the Symbol Library Tree, will now read "Logic Symbols (CresLib xxx)". The "Crestron Modules" node in the Symbol
Library Tree will now read "Crestron Modules (CresDb xx.xx.xx)".
SIMPL Windows: Added logic to the processing of the "Include Standard Commands" option on the Module Header
dialog. When this option is selected, SIMPL Windows will create a Digital Input, in the Default Argument Definition,
for each standard command associated with the selected device type and will now also create a Digital Input
Property item for each of these inputs.
Fixes/Changes from 2.05.06 to 2.05.08:
SIMPL Windows: Implemented 1 level of UNDO for undoing actions that would result in symbol/folder/signal
deletion, signal renames and signal replacements. The Edit menu will show the UNDO option enabled, with a
description of what action would be undone, if there is something in the 'undo buffer'. In addition, there is the Ctl+Z
key sequence and a ToolBar button with an 'undo arrow' that will also perform an Undo of the last action taken by
the operator, if there is something in the 'undo buffer'. Note: The Edit->Undo menu option and the toolbar button
will only be enabled when there is something in the 'undo buffer'.
SIMPL Windows: Updated the Device Help processing such that if the Product Catalog CD can't be found, or if the
CD is found but the appropriate PDF file is not found, SIMPL Windows will fall through and try to find a help subject
in the SIMPL Windows HTML Help.
SIMPL Windows: Disable Help option from the Right Click menu in the Device Library for devices that come from the
CrestronDB. These devices are typically 3rd party and do not have Help information available.
SIMPL Windows: Added logic to the Search and Replace (F9) dialog to replace spaces with underscores if
Comments and Parameters are not to be a part of the search.
SIMPL Windows: Removed "Find Next" button from the Edit Menu->Find Ir File in Crestron/User/Project Database
option as this selection never had any processing.
SIMPL Windows: Made sure a message is displayed if the "Add Device To System" option is selected via right click
menu in the device library, and the device could not be added.
SIMPL Windows: Fixed issues causing AppBuilder to crash.
SIMPL Windows: Made sure error messages are displayed in Error Log if a device is being replaced by another, or
during a replace control system, and signal connections in the new device/control system, could not be copied
over.
SIMPL Windows: Fixed problem with not being able to delete a Module's parameter if parameter properties have
been defined for that parameter.
SIMPL Windows: Fixed problem with user database not allowing .IR files with names longer than 50 characters.
Fixes/Changes from 2.05.05 to 2.05.06:
Fix for CLX lighting module compilation where curve types for Fluorescent 2-Wire, Electronic Low Voltage, and
Magnetic Low Voltage would work only as Non-Dim circuits (i.e. on or off).
Fixes/Changes from 2.05.04 to 2.05.05:
SIMPL Windows: Fixed system crash when trying to change the Net ID of devices in Configuration Manager.
SIMPL Windows: Fixed problem where User/Project Modules that have the same name (minus the same file
extension) as a User/Project SIMPL+ were being flagged as Duplicates and the SIMPL+ module was never getting
loaded in the Symbol Library.
SIMPL Windows: Fixed problem with Replace Control System not transferring over some signals if the system had a
Poll Accelerator in it.
SIMPL Windows: Enforced some legality rules for Passwords on File Encryption:
Passwords will be 1-16 characterss long
Passwords must be printable ASCII characters
Passwords are case insensitive
SIMPL Windows: Made Password Dialog wording clearer
SIMPL Windows: If doing a SAVE AS of a SIMPL Windows program, the file will be saved under the same password
protection state as the original file (e.g. if the current program is encrypted, the new file will be encrypted with the