System information

SIMPL+: Add file encryption for X Generation SIMPL+ compiler.
SIMPL Windows: Analog Input Properties, Analog Output Properties and Parameter Properties will now allow
negative values in the Range selections.
SIMPL Windows: Fix issue when changing control systems: Touchpanel models that had Sleep/Wake inputs would
get the sleep/wake copied to feedback 1 & 2, and feedback 1 from the old definition would get copied to feedback 3
of the new definiton, etc. The fbck inputs are now copied correctly. The signals tied to sleep/wake will be lost,
however, - SIMPL Windows will notify you of this. It is suggested to use a Sleep/Wake Device Extender instead
(Also available in Library Update 269 and later).
Fixes/Changes from 2.05.14 to 2.05.15:
SIMPL Windows: Double clicking on the Logic Folder or any subfolder icon will result in expansion of that part of the
tree (instead acting like Ctrl+D and showing a window in the Detail View)
SIMPL Windows: Added a Right Click context menu option to the Device Library for devices that have Default
Programming available. For those devices, the menu option "Show Inputs/Outputs/Params" will be available. When
selected, a dialog will display listing all inputs, outputs and parameters for the associated Crestron Module that will
be used in programming that device with the default logic.
SIMPL Windows: Correct issue where CNX-DVP4 helpers were seen on the C2N-DVP4DI instead of the C2N-
DVP4DI helpers (Also available in library update 267 and later).
Fixes/Changes from 2.05.13 to 2.05.14:
Fix front panel for MC2E to show C2I-MC2E-FRONTPANEL, not C2I-MC2W-FRONTPANEL. (Also available in library
update 257 and later.)
Fix C2I-RMC-DI4 to show cues i1-i4 instead of all 4 being i1. (Also available in library update 257 and later.)
Show C2N-TXM Radio model (Also available in library update 259 and later).
SIMPL Windows: Fixed problem where dropping a device on the System Configuration tree control from D3Pro or
System Builder was displaying a 'Device already exists' message.
SIMPL Windows: Added ability to program a Crestron device with logic from a .cmc file (i.e. devices in the Device
Library that are not under the User Devices node). If a Crestron device has 'default' logic, a node will be drawn in
the Device Library tree under the node displaying the name of the Crestron Device. The name displayed on these
new levels will be a descriptor defining the capablity that would be provided by the associated logic module. There
can be more than one set of default logic per device in which case, there will be a different node for each logic file.
If the user selects to add the top level device, then no automatic programming will be performed when the device is
added to the program. However, if the user selects to add an instance of the device with it's logic, the user will be
prompted for a Prefix to be used in uniquely naming the signals during the programming process. If the user
requests Help for one of the instances of the device with logic, SIMPL Windows will attempt to display the Help that
is available for the associated logic module. If no help for the module exists, then SIMPL Windows will attempt to
display Help for the generic Crestron device.
Test Manager: Added option to View menu to display a signal's driving source if that driving souce is a device.
Test Manager: Added new File Menu options to Open Port, Close Port and Close Debugging Session.
Test Manager: Added Scroll Lock toolbar button to stop the Trace Window from scrolling but will still take in data
from the system. When turned off, data received during lock will be available.
Test Manager: Added test of selected program versus program in control system. will present warning if they're not
the same.
Test Manager: Added context menu to Status window: include in trace, exclude in trace, remove signal from status
window.
Test Manager: Added context menu to Trace window: exclude from trace, add signal to status window.
Fixes/Changes from 2.05.12 to 2.05.13:
SIMPL Windows: Change Stepper symbol so that it shows delay1/len1 through delay100/len100 (100 steps). (Also
available in library update 252 and later.)
SIMPL Windows: Expandable RoomView symbol now requires SIMPL Windows 2.05.13 or later and Library Revision
256 or later.
Fixes/Changes from 2.05.11 to 2.05.12: